ISSN 1004-4140
CN 11-3017/P
LI Zhang-zheng, SHI Fang-fang, WU He-zhen. Research on Inspecting Concrete Flaws with LFM Signal[J]. CT Theory and Applications, 2014, 23(1): 19-26.
Citation: LI Zhang-zheng, SHI Fang-fang, WU He-zhen. Research on Inspecting Concrete Flaws with LFM Signal[J]. CT Theory and Applications, 2014, 23(1): 19-26.

Research on Inspecting Concrete Flaws with LFM Signal

More Information
  • Received Date: January 13, 2013
  • Available Online: December 09, 2022
  • On account of existing problems of ultrasonic inspecting concrete defect,such as low signal noise ratio(SNR) and limited penetrating depth,the method of exciting with LFM is put forward.Linear frequency modulation(LFM) signal with the characteristics of long time series and wide band width is excited at transmitting terminal,and compressed signal with narrower main lobe and higher SNR will be obtained at receiving terminal through compression method.The effect of transducer's bandwidth is analyzed.The results of numerical calculation show that good compressed results of echo will be obtained if there is much noise.Testing results show that pulse compression method can improve signal-noise ratio.
  • Related Articles

    [1]GAO Rongtao, CHENG Yun, TANG Ziqi, LIU Zhao. Data Processing Solutions on Low Signal-to-Noise Data in Loess Plateau Area- A Case Study in Ordos Basin, China[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.050
    [2]CHEN Jian-yong, WANG Dao-kuo, DENG Wen-feng, YUAN Pei-xin. Application and Research on Reconstructed Wavelet Threshold Functionin Signal Denoising[J]. CT Theory and Applications, 2017, 26(1): 63-68. DOI: 10.15953/j.1004-4140.2017.26.01.08
    [3]ZHANG Jun-hua, ZHU Wen-bo, WU Cheng, XU Ying, WANG Li-xin, HU Zhong-ping. The Analysis and Research of Carbonate Rock Cave Imaging Elements[J]. CT Theory and Applications, 2014, 23(3): 413-423.
    [4]DING Wei-hua, LEI Man, GUO Rui. Reserching on Geometric Correction of Concrete CT Image[J]. CT Theory and Applications, 2012, 21(2): 255-261.
    [5]CAI Dong-shan, SHI Cheng, XING Yu-xiang. Research on Theoretical Estimation of System Performance for 3D X-ray CT with FDK Reconstruction[J]. CT Theory and Applications, 2011, 20(4): 513-522.
    [6]WANG Tian-tian, YU Xiao-e. Identifying of Noise Types for Computed Tomography Images Based on Wavelet Analysis[J]. CT Theory and Applications, 2011, 20(2): 183-190.
    [7]CHANG Ren-min, LIU Guang-bao, ZHANG Yu-zhong, HU Ba-sheng, CHEN Bin, QU Hua-li, XU Yi-kai, QIU Shi-jun, ZHANG Xue-lin. Study of Clinical Applied Characteristics of 3.0T MRI[J]. CT Theory and Applications, 2008, 17(4): 76-81.
    [8]LI Shou-tao, CHEN Hao, ZHU Rui-hui, LI Xiao-mao. Application of CV Active Contour in Weld Defects Detection[J]. CT Theory and Applications, 2008, 17(4): 55-61.
    [9]DING Wei-hua, ZHANG Jian-jun, CHEN Hou-qun, LIU Shao-cong. Test Equipment Problems on Studying Concrete Using X-Ray CT[J]. CT Theory and Applications, 2007, 16(2): 42-47.
    [10]CENG Liang, LI Zhen-yu, WANG Peng. Improveing S/N Ratio of MRS Signal of Detecting Ground Water with Wavelet Analysis[J]. CT Theory and Applications, 2006, 15(2): 1-5.
  • Cited by

    Periodical cited type(0)

    Other cited types(4)

Catalog

    Article views (784) PDF downloads (3) Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return