ISSN 1004-4140
CN 11-3017/P
LI Bin, ZHANG Yao-jun, ZHU Pei-ping, LI Bao-lei, MO Yang. A Fast Simulation Method for CT Projection Based on Bisection[J]. CT Theory and Applications, 2014, 23(1): 115-122.
Citation: LI Bin, ZHANG Yao-jun, ZHU Pei-ping, LI Bao-lei, MO Yang. A Fast Simulation Method for CT Projection Based on Bisection[J]. CT Theory and Applications, 2014, 23(1): 115-122.

A Fast Simulation Method for CT Projection Based on Bisection

More Information
  • Received Date: July 30, 2013
  • Available Online: December 09, 2022
  • Projection simulation is the basis of CT simulation research.A fast simulation method for CT projection based on bisection was proposed in this paper,and then the simulation process was optimized.As long as a scanned object could be decomposed to individual convex items,arbitrary scanning trajectory could be used to simulate projection based on our method,and the projection accuracy could be infinitely close to theoretical projection accuracy.Numerical simulation results verify the effectiveness of our method.
  • Related Articles

    [1]SU Danyang, HOU Ping, ZHANG Haoran, MA Yuanbo, LIU Jinlong, YANG Xiaopeng. Research Progress on Reducing Metal Artifacts in CT Imaging[J]. CT Theory and Applications, 2025, 34(3): 499-505. DOI: 10.15953/j.ctta.2024.023
    [2]CHENG Tianxin, ZHANG Yongxian. Orthopedic Metal Artifact Reduction Combined with Iterative Reconstruction in CT Imaging after Lumbar Internal Fixation[J]. CT Theory and Applications, 2025, 34(2): 285-293. DOI: 10.15953/j.ctta.2024.091
    [3]LIU Xiangcheng, HUANG Xiaoying, WEI Pengyue, WANG Pengchao, GUO Fangkai, BAO Yunfeng. Clinical Research Progress on Deep Learning for Metal Artifact Reduction in CT Images[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.222
    [4]YAN Yongle, MAO Weiyu, GAO Hewei, ZHOU Hao, WANG Zhilei, WU Hongxin, HE Aijing, CHEN Xiaobo. Quantitative Performance and Metal Artifact Reduction of Dual-Energy Cone Beam CT in Human Forearm and Dental Phantom[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.079
    [5]NING xianying, HU Liu, FAN Wenliang, YU Jianming, LEI Ziqiao. The Application Value of Monoenergetic Imaging on Dual-layer Spectral Detector Computed Tomography in Dacryocystography[J]. CT Theory and Applications, 2024, 33(6): 677-682. DOI: 10.15953/j.ctta.2024.144
    [6]ZUO Shunji, FENG Peng, HUANG Pan, YAN Shenghao, HE Peng, WEI Biao. Metal Artifact Reduction Algorithm for CT Images of Rock and Mineral Samples Based on Dual-domain Adaptive Network[J]. CT Theory and Applications, 2022, 31(6): 783-792. DOI: 10.15953/j.ctta.2022.041
    [7]DENG Xiaolin, XIE Hui, QU Yalin, WU Shaoquan, ZHOU Bangjian, YANG Zhengbin, FENG Lian, WANG Min. The Value of Optimal Monochromatic Spectral CT Imaging in Gastric Variceal Bleeding before Endoscopic Treatment[J]. CT Theory and Applications, 2021, 30(5): 603-609. DOI: 10.15953/j.1004-4140.2021.30.05.08
    [8]DENG Xiao-lin, XIE Hui, QU Ya-lin, YANG Shao-wei, YANG Zheng-bin. Spectral CT with Optimal Monochromatic Energy to Improve CTA Image Quality of Head and Neck[J]. CT Theory and Applications, 2018, 27(6): 719-726. DOI: 10.15953/j.1004-4140.2018.27.06.05
    [9]CHAI Jia-bin, LI Gong-ping, WEI Cun-feng, WEI Long, YU Yang, WANG Qian, LIU Bao-dong. Metal Artifacts Correction Method Research about Liquid Metal Angiography[J]. CT Theory and Applications, 2016, 25(2): 149-157. DOI: 10.15953/j.1004-4140.2016.25.02.04
    [10]LI Qing-liang, YAN Bin, SUN Hong-sheng, LI Lei, ZHANG Feng. Review of Metal Artifacts Correction Methods on X-ray Computed Tomography[J]. CT Theory and Applications, 2011, 20(1): 131-140.
  • Cited by

    Periodical cited type(10)

    1. 杨美英,胡继红,赵卫,王滔,马帅,刘芳志. 双层探测器光谱CT单能量成像联合去金属伪影算法在TIPS术后随访的应用价值. 临床放射学杂志. 2025(04): 723-729 .
    2. 王禄丁,张康龙,贠张玲,杨东. 能谱CT联合去金属伪影技术用于髋关节置换术的效果及对成像质量的影响. 大医生. 2025(07): 117-119 .
    3. 李成龙,董丽娜,卢力亚,徐超. 能谱CT与常规CT在漏斗胸矫形钢板植入体模后的辐射剂量与图像质量研究. 中国CT和MRI杂志. 2024(04): 52-54 .
    4. 张欣艺,蒋思懿,黎达琴,李真林,杨帆,程勇,朱小牧,潘雪琳. 光谱CT结合金属伪影去除技术降低乳腺癌患者胸部增强CT对比剂硬化伪影的临床价值. 中华放射学杂志. 2023(12): 1353-1360 .
    5. 施康,储晨,杨尚文,王铭君,李茗,胡安宁,辛小燕. 能谱CT在心脏起搏器植入术后的临床应用研究. 中国医疗设备. 2022(08): 104-107+141 .
    6. 马富强,黄耀渠,袁健祥,张治堂,黄学桥. 能谱CT去金属伪影技术在骨折金属内固定术后的应用. 实用医学影像杂志. 2022(05): 439-441 .
    7. 龙翔,胡凌,吴迎澜,杨扬. CT能谱成像技术去除脊柱金属植入物伪影的临床研究. 当代医学. 2021(29): 4-6 .
    8. 潘雪琳,洪静,袁元,杨帆,邵强,李真林. MAC技术在降低颈椎金属内固定术后CT扫描金属伪影的临床价值. 中国医疗设备. 2021(11): 81-85 .
    9. 李成龙,胡春峰. 单能量CT成像结合去金属伪影算法在儿童漏斗胸金属支架植入术后评估中的应用. 影像诊断与介入放射学. 2020(01): 37-41 .
    10. 陶娜,晏飞虎,郑伟,龚涛,陈龙凤,王樱花. 双能谱CT在头颈CT血管造影消除血管金属植入物伪影的应用价值. 中国当代医药. 2020(35): 164-166 .

    Other cited types(3)

Catalog

    Article views (803) PDF downloads (3) Cited by(13)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return