ISSN 1004-4140
CN 11-3017/P
YAO Wei-wei, XIA Jun, DU Heng-feng, LIU Pin-ni, LUO Xiao, LEI Yi, LIN Fan, WU Hui-sheng. The Diagnostic Value of Quantitative T1WI MR Parametric Perfusion-weighted Imaging Based on DCE-MRI in Duct-borne Breast Cancer[J]. CT Theory and Applications, 2014, 23(1): 131-138.
Citation: YAO Wei-wei, XIA Jun, DU Heng-feng, LIU Pin-ni, LUO Xiao, LEI Yi, LIN Fan, WU Hui-sheng. The Diagnostic Value of Quantitative T1WI MR Parametric Perfusion-weighted Imaging Based on DCE-MRI in Duct-borne Breast Cancer[J]. CT Theory and Applications, 2014, 23(1): 131-138.

The Diagnostic Value of Quantitative T1WI MR Parametric Perfusion-weighted Imaging Based on DCE-MRI in Duct-borne Breast Cancer

More Information
  • Received Date: July 04, 2013
  • Available Online: December 09, 2022
  • Objective:To study the diagnostic value of quantitative T1WI MR parametric perfusion-weighted imaging based on DCE-MRI in duct-borne breast cancer.Methods:16 cases of female were performed the DCE-MRI examination before surgical operation,and the time-intensity curve(TIC) were acquired,then the parameters perfusion images of Wash-in,Wash-out,TTP,MIPt and PEI were drawn out by the special software for breast.And then measured the parameters of perfusion,analyzed the features of perfusion of duct related breast cancers.Results:13 cases invasive ductal carcinoma and 3 cases ductal carcinoma in situ were confirmed by pathology in the 16 cases.13 cases were non-mass-like enhancement,such as 7 cases duct-like,5 cases patchy,1 case spot-like.Another 3 cases were mass enhancement.All of the 16 cases TIC were the type II.13,10,9,15 and 16 lesions were found in the five kinds of parametric images.The detection rates were 81.25%,62.50%,56.25%,93.75% and 100%,respectively.We found the parameters between lesions and normal breast tissue were significant difference(P<0.001).Moreover,the parameters between periphery and centre of lesions was also significant(P<0.001),except in the TTP.But there's no significant difference between the invasive ductal carcinoma and the ductal carcinoma in situ.Conclusion:Quantitative T1WI MR parametric perfusion-weighted imaging based on DCE-MRI has a high detection rate of the duct-borne breast cancers,and might provide important additional information for its diagnosis and differential diagnosis.
  • Related Articles

    [1]HU Juan, TANG Guangjian, YANG Xuedong, WANG Xiaoying, LIU Jing, GUO Xiaochao. Optimization of the Measurement of CT Perfusion Parameters of Rectal Carcinoma Recurrence[J]. CT Theory and Applications, 2019, 28(2): 213-220. DOI: 10.15953/j.1004-4140.2019.28.02.07
    [2]YANG Xiao-feng, ZHA Yun-fei, LI Liang. Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor[J]. CT Theory and Applications, 2016, 25(6): 717-723. DOI: 10.15953/j.1004-4140.2016.25.06.13
    [3]TAN Zheng-wu, REN Ke. Application Status and Research Trends of the Low-dose CT Perfusion Imaging of Pancreas[J]. CT Theory and Applications, 2015, 24(6): 865-872. DOI: 10.15953/j.1004-4140.2015.24.06.13
    [4]DING Bei, ZHANG Huan, JIANG Hong, HUANG Juan, LING Hua-wei. Application of Quantitative CT Perfusion Imaging in the Diagnosis of Adult Moyamoya Disease[J]. CT Theory and Applications, 2015, 24(1): 123-128. DOI: 10.15953/j.1004-4140.2015.24.01.15
    [5]ZHU Lan, PAN Zi-lai. The Utilization of Diffusion-weighted Magnetic Resonance Imaging in the Detection of Lymph-node Metastasis in Rectal Cancer[J]. CT Theory and Applications, 2014, 23(3): 527-533.
    [6]ZU De-gui, ZENG Qing-yu, HUO Jian-wei. The Clinical Value of 64-row Spiral CT Perfusion for Diagnosis of Pulmonary Masses[J]. CT Theory and Applications, 2009, 18(4): 90-95.
    [7]WANG Fang-jun, CHEN Wei-chang, GUO Liang, FANG Xiang-ming, LIU Peng-fei. The Study to the Multisection Dynamic CT Perfusion on Normal Pancreas[J]. CT Theory and Applications, 2009, 18(2): 83-91.
    [8]DENG Jia-xiu, ZHANG Yong-dong, FENG Feng-yin, LIU Juan, CHEN Yu-ying. A Preliminary Study of CT Perfusion Imaging and Dynamic Enhanced for Lung Nodule[J]. CT Theory and Applications, 2008, 17(2): 66-73.
    [9]ZHAO Yan, SHI Qiao-lian. A Low Profile Monopole Antenna for Breast Cancer Imaging[J]. CT Theory and Applications, 2008, 17(2): 34-39.
    [10]XIANG Zi-yun, YIN Liang, YE Qu-yang, ZHAN Yong, WANG Jing-bo, LUO Liang-ping. The Multislice CT Perfusion Imaging in Uterus and Uterine Leiomyoma[J]. CT Theory and Applications, 2007, 16(4): 38-43.

Catalog

    Article views (787) PDF downloads (11) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return