• Key Magazine of China Technology(CSTPCD)
ISSN 1004-4140
CN 11-3017/P
LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.
Citation: LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.

The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors

More Information
  • Received Date: November 11, 2013
  • Available Online: December 09, 2022
  • Artifacts will be introduced into the reconstruction for fan-beam CT system if the central X-ray is not perpendicular to the detector array, and the image quality will degrade consequently. In this study, the reasons for the formation of such artifacts are analyzed based on the classic theory of filtered back projection algorithm, and a novel method is proposed to calculate the geometric parameters necessary based on sinogram features. The image quality can be improved when we put these parameters into the revised algorithm. The newly proposed method requires no correction phantom, thus avoiding twice scan. Computer simulation and experimental results demonstrate that the method is easy, fast, and effective for practical utilization.
  • Related Articles

    [1]SHI Wuliang, ZOU Xiang, CHEN Changyu, XING Yuxiang. Differentiated Backprojection Reconstruction Method for Square Cross-section Fielid-of-view Rotational Computed Laminography[J]. CT Theory and Applications, 2025, 34(4): 621-631. DOI: 10.15953/j.ctta.2024.113
    [2]CAO Juntao, CHEN Qiqi, HU Ming, XU Ting, TU Jianchun, ZHANG Huan. A Preliminary Analysis of Using the Sinogram-affirmed Iterative Reconstruction Strength Levels based on the Original Data of Low-dose Chest CT to Evaluate Different Types of Small Pulmonary Nodules[J]. CT Theory and Applications, 2021, 30(6): 735-742. DOI: 10.15953/j.1004-4140.2021.30.06.09
    [3]LV Zhentao, GUI Zhiguo, LIU Yi, ZHANG Pengcheng. Industrial CT Rotation Center Calibration Method Based on Weighted Average[J]. CT Theory and Applications, 2021, 30(5): 539-546. DOI: 10.15953/j.1004-4140.2021.30.05.01
    [4]WANG Jing-yu, HAN Yu, LI Lei, XI Xiao-qi, SUN Yan-min, YAN Bin. A Novel Reconstruction Algorithm Based-on Projection Transformation for the Rotational Cone-beam CL[J]. CT Theory and Applications, 2017, 26(5): 575-582. DOI: 10.15953/j.1004-4140.2017.26.05.06
    [5]WU Wen-shu, WANG Zhe, SHI Yi-fan, ZHAO Zhan-shan, WEI Cun-feng, WEI Long. Noise Reduction for Low-dose CT Sinogram Based on PDE[J]. CT Theory and Applications, 2017, 26(2): 177-188. DOI: 10.15953/j.1004-4140.2017.26.02.06
    [6]LI Zeng-yun, LÜ Dong-hui. Fast-correction of Rotating Center Offset with Part Views Sinogram in 2D CT[J]. CT Theory and Applications, 2015, 24(4): 533-543. DOI: 10.15953/j.1004-4140.2015.24.04.07
    [7]CHEN Yan-hua, YUAN Xia-bing, XIE Jin, LI Yi, XU Wei-dong, HU Wei, PAN Hua-su, YANG Yong-xin, YANG Yong. Parallel-beam Algorithm and its Application in Breast Panel-PET[J]. CT Theory and Applications, 2014, 23(6): 923-929.
    [8]YU Bai-hui, ZHAO Zi-ran, WANG Xue-wu, WU Du-fan, YI Heng-guan, ZENG Zhi, CHENG Jian-ping. Cause Analysis and Correction Method of the Center Layer Artifact in Cosmic-ray Muon Radiography[J]. CT Theory and Applications, 2014, 23(3): 385-394.
    [9]WANG Xian-gang, ZHANG Chao-zong, GUO Zhi-ping. Automatic Method of Rotation Center Determination with Hough Transform and Thin Cylinder Phantom[J]. CT Theory and Applications, 2010, 19(4): 1-6.
    [10]WANG Xue-li. Medical CT Artifact Analysis: Reason and Correction[J]. CT Theory and Applications, 2004, 13(3): 1-8.

Catalog

    YANG Min

    1. On this Site
    2. On Google Scholar
    3. On PubMed
    Article views (1139) PDF downloads (28) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return