LIU Huan, FU Quan-hai, CHEN Xiao-Zhao, HOU Yao-fang, SUN Zhi-yong, KANG Yan. Design and Evaluation of Dental CT Test Phantom[J]. CT Theory and Applications, 2014, 23(6): 959-966.
Citation: LIU Huan, FU Quan-hai, CHEN Xiao-Zhao, HOU Yao-fang, SUN Zhi-yong, KANG Yan. Design and Evaluation of Dental CT Test Phantom[J]. CT Theory and Applications, 2014, 23(6): 959-966.

Design and Evaluation of Dental CT Test Phantom

More Information
  • Received Date: April 20, 2014
  • Available Online: December 09, 2022
  • Phantom is widely used to evaluate CT image quality objectively. Currently, only DIGIDENT Phantom is exclusively used in evaluating image performance of Dental CT. This phantom was recommended by "YY/T 0795-2010 Particular specification for oral cavity X-ray equipment for digital tomography". Although most of image parameters can be tested by this phantom, there are still disadvantages with it. For example, no module for slice thickness measurement and the density resolution and spatial resolution module can be improved. Hence, this paper proposed an innovative phantom which can not only be used to evaluate image quality of dental CT, but also be suitable for the dual-energy subtraction experiment. By experimental verification, the performance of this phantom is much better than existed DIGIDENT Phantom when evaluating dental CT's image quality. A new phantom design and evaluation way were presented, which will contribute to the development of dental CT phantom.
  • Related Articles

    [1]SHANG Xiaoqing, CHEN Yingmin, LIU Xiang, GAO Huimin, JIA Xiuchuan, BAO Yunfeng. The Value of Dual-energy CT Virtual Calcium Subtraction Technique in the Diagnosis of Fresh Sacrococcygeal Fractures in the “Sitting Position”[J]. CT Theory and Applications, 2024, 33(6): 725-732. DOI: 10.15953/j.ctta.2024.095
    [2]GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08
    [3]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [4]ZHANG Chao-zong. System Structure and Performance Parameters of Industrial CT[J]. CT Theory and Applications, 2014, 23(3): 443-452.
    [5]CHEN Jian, HUANG Zheng-ren, LIU Xue-jian, YANG Jin-jing, CHEN Zhong-ming, LIU Yan, YUAN Ming, ZHU Yun-zhou. The Relationship between the Optimal Magnification and the Limit Spatial Resolution in CT System[J]. CT Theory and Applications, 2014, 23(1): 37-43.
    [6]FENG Mei, AN Mei-jian. How to Determine Spatial Resolution for an Inverse Problem[J]. CT Theory and Applications, 2013, 22(4): 587-604.
    [7]QUE Jie-min, WANG Yan-fang, LIU Li. Experimental Research on Improving the Spatial Resolution by Using the Method of Pixel Offset Scanning[J]. CT Theory and Applications, 2009, 18(1): 83-87.
    [8]ZHAN Jie, YU Xiao-e. Practice and Study on Automatic Measurement of CT Spatial Resolution[J]. CT Theory and Applications, 2006, 15(2): 43-46.
    [9]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [10]CHEN Wei-chang, CHEN Zhi-hua, ZHAO Tian-de, WANG Zi-qiang. Improvement of CT Contrast (Density) Resolution By Dual Photons Absorption Method[J]. CT Theory and Applications, 2002, 11(4): 5-8.

Catalog

    Article views (840) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return