ISSN 1004-4140
CN 11-3017/P
TAN Zheng-wu, REN Ke. Application Status and Research Trends of the Low-dose CT Perfusion Imaging of Pancreas[J]. CT Theory and Applications, 2015, 24(6): 865-872. DOI: 10.15953/j.1004-4140.2015.24.06.13
Citation: TAN Zheng-wu, REN Ke. Application Status and Research Trends of the Low-dose CT Perfusion Imaging of Pancreas[J]. CT Theory and Applications, 2015, 24(6): 865-872. DOI: 10.15953/j.1004-4140.2015.24.06.13

Application Status and Research Trends of the Low-dose CT Perfusion Imaging of Pancreas

More Information
  • Received Date: June 17, 2015
  • Available Online: December 08, 2022
  • At present, imaging diagnosis of the pancreas is gradually changed from the single morphological diagnosis to combining of morphological and functional diagnosis in the CT perfusion; CT perfusion is a kind of functional imaging technology developed on the basis of conventional CT scan, which could earlier detect and diagnose the pancreatic diseases by observing the pancreas microcirculation changes using CT perfusion. It is a hotspot in the research field of the pancreas disease. Radiation dose was significantly increased using CT perfusion scanning with conventional scanning conditions. How to do low dose CT perfusion becomes the key direction of current discussion. This review deals with the application status and research trends of the technology in the low-dose CT perfusion imaging of pancreas.
  • Related Articles

    [1]HUANG Xiaoying, LI Xiamin, GUO Fangkai, WANG Pengchao, SHAN Chunhui, BAO Yunfeng. Combining Low-dose Perfusion with Dual-energy CT Scanning for Pancreatic Neuroendocrine Tumors[J]. CT Theory and Applications, 2025, 34(3): 369-375. DOI: 10.15953/j.ctta.2024.348
    [2]HU Juan, TANG Guangjian, YANG Xuedong, WANG Xiaoying, LIU Jing, GUO Xiaochao. Optimization of the Measurement of CT Perfusion Parameters of Rectal Carcinoma Recurrence[J]. CT Theory and Applications, 2019, 28(2): 213-220. DOI: 10.15953/j.1004-4140.2019.28.02.07
    [3]YANG Xiao-feng, ZHA Yun-fei, LI Liang. Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor[J]. CT Theory and Applications, 2016, 25(6): 717-723. DOI: 10.15953/j.1004-4140.2016.25.06.13
    [4]DING Bei, ZHANG Huan, JIANG Hong, HUANG Juan, LING Hua-wei. Application of Quantitative CT Perfusion Imaging in the Diagnosis of Adult Moyamoya Disease[J]. CT Theory and Applications, 2015, 24(1): 123-128. DOI: 10.15953/j.1004-4140.2015.24.01.15
    [5]YUAN Qing-cheng, QU Ya-mei, ZHANG Nian-qiu, LAI Jian-hua. The Value of Spiral CT Perfusion Imaging in Diagnosis of Adrenal Hyperplasia[J]. CT Theory and Applications, 2011, 20(2): 283-289.
    [6]ZU De-gui, ZENG Qing-yu, HUO Jian-wei. The Clinical Value of 64-row Spiral CT Perfusion for Diagnosis of Pulmonary Masses[J]. CT Theory and Applications, 2009, 18(4): 90-95.
    [7]WANG Fang-jun, CHEN Wei-chang, GUO Liang, FANG Xiang-ming, LIU Peng-fei. The Study to the Multisection Dynamic CT Perfusion on Normal Pancreas[J]. CT Theory and Applications, 2009, 18(2): 83-91.
    [8]DENG Jia-xiu, ZHANG Yong-dong, FENG Feng-yin, LIU Juan, CHEN Yu-ying. A Preliminary Study of CT Perfusion Imaging and Dynamic Enhanced for Lung Nodule[J]. CT Theory and Applications, 2008, 17(2): 66-73.
    [9]XIANG Zi-yun, YIN Liang, YE Qu-yang, ZHAN Yong, WANG Jing-bo, LUO Liang-ping. The Multislice CT Perfusion Imaging in Uterus and Uterine Leiomyoma[J]. CT Theory and Applications, 2007, 16(4): 38-43.
    [10]ZHANG Yuan, SUN Yong-guang, GAO Shu-ming, HAN Xiang-jun. CT Perfusion Imaging of the Liver and Its Study Headway[J]. CT Theory and Applications, 2007, 16(1): 70-76.

Catalog

    Article views (680) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return