LIU Li, JIN Mei, SHEN Jian, LIN Yi-jun, GAO Zhen-xing, WANG Kai-le, CHEN Tong. Application Value of the Research Dual-energy CT Color Coding Technique to Patients with Gout Deposition of Monosodium Urate[J]. CT Theory and Applications, 2016, 25(3): 339-348. DOI: 10.15953/j.1004-4140.2016.25.03.10
Citation: LIU Li, JIN Mei, SHEN Jian, LIN Yi-jun, GAO Zhen-xing, WANG Kai-le, CHEN Tong. Application Value of the Research Dual-energy CT Color Coding Technique to Patients with Gout Deposition of Monosodium Urate[J]. CT Theory and Applications, 2016, 25(3): 339-348. DOI: 10.15953/j.1004-4140.2016.25.03.10

Application Value of the Research Dual-energy CT Color Coding Technique to Patients with Gout Deposition of Monosodium Urate

More Information
  • Received Date: January 20, 2016
  • Available Online: December 01, 2022
  • Published Date: June 24, 2016
  • Objective: To evaluate dual source CT dual energy(DECT) color coding technology in patients with gout urate crystals and different clinical period the relationship, between blood uric acid and further evaluation of dual-energy CT imaging in the gout screening application value. Methods: Retrospective analysis 120 cases of patients with Hyperuricemia or gout dual-energy CT imaging characteristics and clinical data, According to the clinical stage can be divided into two groups of 92 cases of male and female 28 cases; 30 cases of control group for the pseudogout patients, male 26 cases, female 4 cases, All cases of hand, footline DECT non enhanced scan, thin layer after restructuring would transmit the original data to choose MMWP workstation Dual Energy GOUT software, image post-processing, comparing the difference between the patients with GOUT two uric acid salt deposition and uric acid value relevance, and DECT detection urate deposition area and the difference of clinical evaluation. Using t test and chi-square test, Fisher exact probability statistical analysis. Results: Three groups of gender and age, there was no statistically significant difference(Page= 0.236, Pgender= 0.613, P > 0.005). Urate deposition quantity high uric acid group was obviously higher than that of uric acid in the normal group, two groups have significant statistical significance(P = 0.00013, P < 0.001); Gout group detection rate compared with the control group, with significant difference statistically significant(P = 0.00015, P < 0.001). Conclusion: DECT imaging of urate crystals, the deposition has a good ability of hyperuricemia, early gout patients and suspected gout have a higher detection rate, can be used as a routine examination gout screening project, has high clinical value.
  • Related Articles

    [1]SI Youqiang, GUO Runhua, LI Mengru. Application of Optimal Noise Reduction Smooth Model Based on EMD and EEMD in Seismic Waves[J]. CT Theory and Applications, 2020, 29(1): 11-21. DOI: 10.15953/j.1004-4140.2020.29.01.02
    [2]DU Jian-peng, LIANG Hai-xia, WEI Su-hua. Abel Transformation Based Adaptive Regularization Approach for Image Reconstruction[J]. CT Theory and Applications, 2017, 26(4): 435-445. DOI: 10.15953/j.1004-4140.2017.26.04.05
    [3]YOU Long-ting, SONG Jian-guo, YU Hui-zhen, WANG Yue-lei. Analysis of the Influence Factors on the Time-Frequency Spectrum Obtained by Synchrosqueezing Wavelet Transform based on Reconstruction of Analytic Signal[J]. CT Theory and Applications, 2017, 26(3): 267-278. DOI: 10.15953/j.1004-4140.2017.26.03.02
    [4]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [5]FAN Hua, ZHAO Guo-chun, HAN Yan-jie, LIU Ming-jun, LI Xiao-qin, SUN Yong-jun. Image Fusion in Combination of the Improved IHS Transform and Wavelet Transform[J]. CT Theory and Applications, 2014, 23(5): 761-770.
    [6]QIAO Zhi-wei. On Implementation and Stability Analysis of Two Types of Finite Hilbert Transforms Used in Backprojection Filtration Algorithms[J]. CT Theory and Applications, 2014, 23(4): 561-568.
    [7]YU Guang-hui, LU Hong-yi, ZHU Min, WANG Xing-bo, WANG Hong-ling. Defects Location Method of CT Image Based on Similarity Transformation[J]. CT Theory and Applications, 2012, 21(1): 37-42.
    [8]XUE Hui, ZHANG Li, LIU Yi-nong. Overview of Nonuniform Fast Fourier Transformation[J]. CT Theory and Applications, 2010, 19(3): 33-46.
    [9]Zhang Tie, Yan Jiabin. The Error Analysis of Improved Fourier Algorithm for Solving Radon Transform[J]. CT Theory and Applications, 2000, 9(1): 12-16.
    [10]Wang Jinping. The Inversion Formula of Radon Transform in R2[J]. CT Theory and Applications, 2000, 9(1): 8-11.

Catalog

    Article views (644) PDF downloads (9) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return