ISSN 1004-4140
CN 11-3017/P
MING Jian-zhong, LIU Tao, XIANG Cheng-xian, CHOU Rong, WU Jing-lan. Diagnostic Value of Enhanced CT Scan in Emergency Patients with Trauma Emergency[J]. CT Theory and Applications, 2017, 26(2): 247-252. DOI: 10.15953/j.1004-4140.2017.26.02.14
Citation: MING Jian-zhong, LIU Tao, XIANG Cheng-xian, CHOU Rong, WU Jing-lan. Diagnostic Value of Enhanced CT Scan in Emergency Patients with Trauma Emergency[J]. CT Theory and Applications, 2017, 26(2): 247-252. DOI: 10.15953/j.1004-4140.2017.26.02.14

Diagnostic Value of Enhanced CT Scan in Emergency Patients with Trauma Emergency

More Information
  • Received Date: October 19, 2016
  • Available Online: November 27, 2022
  • Objective: To analyze the diagnostic value of multi-slice CT in the diagnosis of trauma patients. Methods: A retrospective analysis was performed on 15 cases of emergency patients with critical disease after trauma, and the data of emergency plain and enhanced CT were retrospectively analyzed. Results: 15 cases of acute trauma patients, 8 cases of pelvic fractures(CT contrast-enhanced A. with arterial hemorrhage: 1 cases of left common iliac artery rupture, 5 cases with unilateral internal iliac artery branch bleeding, 2 cases of bilateral internal iliac artery branch bleeding; b. 2 cases with hepatic rupture and 3 cases with spleen rupture); small intestine and mesentery and multiple fracture 1 cases with rupture of liver and spleen; liver rupture in 1 cases; 4 cases of splenic rupture; left superior gluteal artery rupture in 1 cases. Enhanced CT can directly display the contrast extravasations and organ rupture injury changes. Conclusion: Multi slice spiral CT enhanced display with comparison of plain CT scan has important clinical application value of vascular rupture and organ hemorrhage location, the conditions of the hospital can be an active application.
  • Related Articles

    [1]SUN Furong, PAN Zilai. Study on Multi-slice Spiral CT Enhanced Scanning of Accessory Middle Colonic Artery in Normal Population[J]. CT Theory and Applications, 2022, 31(2): 195-202. DOI: 10.15953/j.ctta.2021.011
    [2]ZHU Huaqiang, LUO Dongmei, CAO Li, LIANG Mingli, YOU Rui, WU Bingyun. Application of Personalized Low Dose Spiral CT Scanning in the Examination of Thoracolumbar Trauma[J]. CT Theory and Applications, 2019, 28(1): 111-120. DOI: 10.15953/j.1004-4140.2019.28.01.12
    [3]XUE Feng, SUN Dan, LI Ma-xuan-xuan, QIAO Zhong-yun, DAN Hua. CT Double Phase Enhanced Scan to Thyroid Adenoma and Nodular Thyroid in Differential Diagnosis Value[J]. CT Theory and Applications, 2016, 25(4): 471-476. DOI: 10.15953/j.1004-4140.2016.25.04.11
    [4]YANG Fei, HAN Shuai, CHEN Jing, WANG Da-wei, CUI Shu-jun, GENG He-qun, LI Chuan-gui. Comparative Imaging Study of the Abdominal Aorta and its Branches with CT Enhanced Scanning and MR Enhanced Scanning[J]. CT Theory and Applications, 2016, 25(1): 79-84. DOI: 10.15953/j.1004-4140.2016.25.01.10
    [5]FANG Wen-chun, LAI Li-mei, WU Zhi-guo, WU Bin, SONG Li-le, LUO Xiao-dong. Multislice Spiral CT Scanning on Chest of Optimization of Therapeutic[J]. CT Theory and Applications, 2013, 22(3): 493-499.
    [6]ZHANG Yuan-fang, LIU Guo-rui, FANG Wen-hui, GUO Yue-lin, LI Yang-kang. The Application of High Pressure Injector in CT Contrast Enhancement[J]. CT Theory and Applications, 2004, 13(2): 46-50.
    [7]SUN Cun-jie, LI Gang, HU Wei, WANG Guo-ming, XU Kai, CHENG Guang-jun. Value of Enhanced Scanning Techniques with Multi-slice Helical CT for Liver[J]. CT Theory and Applications, 2004, 13(1): 7-9.
    [8]XU Chun-lin, LIU Wei, WANG Jian-guo, PENG Lei, ZHANG Xue-mei, KANG Su-ping. Value of High Resolution CT and Spiral CT Enhanced Scanning in Diagnosis of Small Peripheral Lung Cancer[J]. CT Theory and Applications, 2003, 12(3): 26-30.
    [9]LIU Jian-xin, YANG Feng-qin, YIN Xiao-ming. Discussion of Quality Evaluation for Tri-phase Enhancement Liver Scan using Multiple Detector Spiral CT[J]. CT Theory and Applications, 2002, 11(4): 17-20.
    [10]Li Ronghuan, Li Jinzhi, Li Xinhua, Zhang Haining, Cui Wenguo. Prevention and Management of Side-effect of Contrast Media in CT Enhancemant Scan[J]. CT Theory and Applications, 2000, 9(3): 20-22.

Catalog

    Article views (737) PDF downloads (6) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return