ISSN 1004-4140
CN 11-3017/P
ZHOU Jing-ran, CHA Yun-fei, YANG Feng. Feasiblity of Low-dose Neck Enhancement MDCT Based on Lower Neck Transverse Diameter[J]. CT Theory and Applications, 2017, 26(3): 349-356. DOI: 10.15953/j.1004-4140.2017.26.03.12
Citation: ZHOU Jing-ran, CHA Yun-fei, YANG Feng. Feasiblity of Low-dose Neck Enhancement MDCT Based on Lower Neck Transverse Diameter[J]. CT Theory and Applications, 2017, 26(3): 349-356. DOI: 10.15953/j.1004-4140.2017.26.03.12

Feasiblity of Low-dose Neck Enhancement MDCT Based on Lower Neck Transverse Diameter

More Information
  • Received Date: December 11, 2016
  • Available Online: November 27, 2022
  • Objective: To explore the feasibility of low-dose neck enhancement MDCT based on the lower neck transverse diameter. Methods: One hundred and twenty-six consecutive patients with suspected of cervical disease undergoing 64-MDCT were prospectively selected and divided into 2 groups at random: conventional group and low dose group. According to the lower neck transverse diameter the low dose group were divided into 3 subgroups at large diameter (group A, diameter ≥ 40cm, n = 21) or medium diameter (group B, 35cm 〈 diameter 〈40cm, n = 35) or small diameter (group C, diameter〈35cm, n = 28). The tube voltage/tube current of conventional group was 120kV/350mA. And that of low dose were 120kV/300mA, 100kV/300mA, 80 kV/300 mA in A, B, C group, respectively. The dose-length product (DLP) and CT dose index volume (CTDIvol) of each group were recorded, and then the effective radiation dose (ED) were calculated. The image quality and radiation dose were evaluated and compared among 4 groups. Results: The radiation dose of 4 groups were respectively 1.34 mSv ±0.13 mSv, 1.17 mSv ±0.10 mSv, 0.74 mSv ±0.08 mSv, 0.34 mSv ±0.04mSv, the difference was statistically significant (F= 606.13, P < 0.01), the effective radiation dose of A, B, C group was significantly lower than that in the conventional group. There was significant difference between arbitrary two of the four groups, respective (all P < 0.01). Kappa conformance test showed that the image quality scores determined by two physicians were highly consistent with each other (all Kappa value 〉 0.70). No significant difference in image quality (Z = -0.258, P > 0.05) and contrast to noise of 4 groups (F = 0.750, P > 0.05). Conclusion: Based on patient's lower neck transverse diameter, neck enhancement MDCT with different suitable tube voltage can effectively reduce the radiation dose, while high quality image of neck structure can still be ensured.
  • Related Articles

    [1]FENG Weiyu, SHEN Xuzhang, TAN Jiawei, WANG Wentian. Influence of Ambient Noise Source Distributions on Cross-correlation Derived Seismic Waveforms and Dispersion Curve Retrieval[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.181
    [2]CHAI Jun, LIANG Danyan, WANG Xiaolan, ZHAO Jianhua. Correlation between Clinical Outcome and Computed Tomography Findings in Coronavirus Disease 2019[J]. CT Theory and Applications, 2023, 32(5): 621-626. DOI: 10.15953/j.ctta.2023.048
    [3]ZHANG Wenchao, LI Jingxu, GUAN Yubao, YANG Xinguan, XIA Tingting, ZHANG Liyi, CHEN Yeying, DONG Xiao. Correlation between CT Features and Patient's Prognosis of Multiple Primary Lung Cancer[J]. CT Theory and Applications, 2019, 28(1): 29-38. DOI: 10.15953/j.1004-4140.2019.28.01.03
    [4]ZHANG Qiu-yi, XU Kai, CHEN Kai, LIU Chen, WEN Lei. Correlation Analysis of Imaging Score and Clinical Manifestation of Tibial Stress Fracture in Soldiers[J]. CT Theory and Applications, 2017, 26(6): 783-790. DOI: 10.15953/j.1004-4140.2017.26.06.16
    [5]BAI Juan-juan, YANG Yu-shuang, WANG Hai-peng. Spatial Registration of X-ray CT Projection Images[J]. CT Theory and Applications, 2016, 25(6): 661-670. DOI: 10.15953/j.1004-4140.2016.25.06.06
    [6]LI Zeng-yun, LÜ Dong-hui. Fast-correction of Rotating Center Offset with Part Views Sinogram in 2D CT[J]. CT Theory and Applications, 2015, 24(4): 533-543. DOI: 10.15953/j.1004-4140.2015.24.04.07
    [7]ZHAO Yue, SHEN Bi-xian, TAN Si-ping, YANG Chun-yu, CHEN Sheng-ji, HUANG An-rong. Study on the Value of Dual Source CT Assessment of Smoking and Coronary Plaque Correlation[J]. CT Theory and Applications, 2014, 23(4): 541-550.
    [8]LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.
    [9]SHEN Jin-song, SUN Wen-bo. Tomography of the Cross-Hole Electromagnetic Measurements[J]. CT Theory and Applications, 2008, 17(1): 27-40.
    [10]ZHOU Le-fu, XIANG Zi-yun. Correlation of CT Findings of Acute Pancreatitis with Changing of Serum and Urine Amykase[J]. CT Theory and Applications, 2004, 13(2): 54-56.
  • Cited by

    Periodical cited type(4)

    1. 张元飞. 动态增强磁共振成像联合弥散加权成像对前列腺癌的诊断效能. 实用临床医药杂志. 2024(24): 26-30 .
    2. 殷帅涛,王嘉南,蒋召强,王向阳,姬彤宇,单磊. PI-RADS v2.1评分联合前列腺特异性抗原衍生指标对灰区前列腺癌的诊断价值. 中华实用诊断与治疗杂志. 2023(04): 372-376 .
    3. 李媛媛,张显利. f-PSA/t-PSA联合基于PI-RADS v2评分的多参数MRI在前列腺癌中的诊断价值. 临床医学研究与实践. 2022(28): 119-122+136 .
    4. 孙东方,姚伟根,刘洁,鲁鹏聪,康聪. 基于PI-RADS联合PSA及衍生物构建前列腺癌定量评分体系的研究. 现代实用医学. 2022(12): 1564-1566 .

    Other cited types(2)