ISSN 1004-4140
CN 11-3017/P
GAO Yun, GUAN Xueni, RONG Lan, ZHOU Lei, LIANG Zonghui. Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity[J]. CT Theory and Applications, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09
Citation: GAO Yun, GUAN Xueni, RONG Lan, ZHOU Lei, LIANG Zonghui. Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity[J]. CT Theory and Applications, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09

Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity

More Information
  • Received Date: May 16, 2019
  • Available Online: November 07, 2021
  • Published Date: August 24, 2019
  • Objective: Investigate the CT value changes of creeping fat around the intestinal segment in Crohn's disease(CD).Methods: From January 2010 to March 2019, 31 patients with active CD(study group) and 31 age and gender matched inactive CD patients/healthy people(control group) were enrolled in the study.The people of study group and control group were tested for CT values of mesentery near the inflammatory intestinal wall, including CT values in plain scan, arterial phase, venous phase and delayed phase.Clinical data including enteroscopy and its pathological results, and clinical immunosuppressive therapy were collected.Results: There were 31 patients(26 males and 5 females) with active Crohn's disease(CD) in the study group.There were 31 patients(22 males and 11 females) in control group.The CT value of creeping fat in patients with Crohn's disease in active stage is higher than that in inactive CD patients/healthy people, and there may be sustained mild enhancement after enhancement over time.Conclusion: The creeping fat along the mesenteric border of bowel inflamed segments of CD can be denser and continuously strengthened during the active stage of the disease, so the change of CT value of the creeping fat around the intestinal tube has diagnostic value for Crohn's disease activity.
  • Related Articles

    [1]YAO Biao, LI Xiaofeng, LIU Caiyun, SHI Yan. Application of Energy Spectral CT in the Diagnosis of Acute Pulmonary Embolism and Evaluation of Pulmonary Perfusion Changes[J]. CT Theory and Applications, 2019, 28(6): 693-699. DOI: 10.15953/j.1004-4140.2019.28.06.07
    [2]SHI Liping, ZHANG Yaping, XIE Xueqian, JIANG Beibei, CHEN An. Quantitative Feature Change of Pulmonary Subsolid Nodule on CT Image to Determine Its Invasiveness[J]. CT Theory and Applications, 2019, 28(5): 541-548. DOI: 10.15953/j.1004-4140.2019.28.05.03
    [3]DAI Yan-zeng, ZHANG Yan, QIU Shu-fen. CT Diagnosis Value of Tubal Pathological Changes[J]. CT Theory and Applications, 2017, 26(4): 511-517. DOI: 10.15953/j.1004-4140.2017.26.04.14
    [4]FAN Bing, WANG Xiao-ying, QIU Jian-xing, GUO Xiao-chao, DONG Jian, GONG Kan. Evaluation of Urinary Calculi: A Comparison of CT Values between Spectrum CT and Conventional CT[J]. CT Theory and Applications, 2016, 25(4): 403-408. DOI: 10.15953/j.1004-4140.2016.25.04.03
    [5]LIU Ze-qun, SUN Mei-yu, LIU Ai-lian, HAN Zheng. Influence of the Size of Regions of Interest on CT Value and Material Decomposition Measurement in Water Phantom by Single-source Dual Energy CT[J]. CT Theory and Applications, 2016, 25(2): 129-134. DOI: 10.15953/j.1004-4140.2016.25.02.01
    [6]CHEN Yun-bin, WANG Yuan, LIU Qing-hua. A CT Number Conversion Method of Cone Beam CT[J]. CT Theory and Applications, 2015, 24(4): 553-561. DOI: 10.15953/j.1004-4140.2015.24.04.09
    [7]ZHANG Hai-bo, FU Chuan-ming, ZHAO Yun, CHEN Lun-gang, XU Lin, WANG Kai-hua. The Study of CT Dynamic Changes and Clinical Comparison in Neonatal Hypoxic-ischemic Encephalopathy Treated by Hyperbaric Oxygen[J]. CT Theory and Applications, 2012, 21(3): 493-499.
    [8]JI Shu-wen, CHAO Hui-min, GAO Bin, CHEN Wang. The Research and Solution Scheme on Relationship between Dual-Source CT Coronary Artery CTA Artifact and Heart Rate Change[J]. CT Theory and Applications, 2011, 20(3): 377-382.
    [9]ZHOU Le-fu, XIANG Zi-yun. Correlation of CT Findings of Acute Pancreatitis with Changing of Serum and Urine Amykase[J]. CT Theory and Applications, 2004, 13(2): 54-56.
    [10]HUANG Shao-quan, XIANG Nian-hu. CT Findings of Cervical Spine Disk Pathological Changes and It's Clinical Significance[J]. CT Theory and Applications, 2002, 11(2): 39-41.
  • Cited by

    Periodical cited type(2)

    1. 黄春嘉. CT鉴别诊断胰腺神经内分泌肿瘤的方法及价值. 现代医用影像学. 2020(08): 1462-1464 .
    2. 李海娜,刘军. 胰腺神经内分泌肿瘤的影像学表现与临床病理分析. 中国继续医学教育. 2020(26): 139-142 .

    Other cited types(0)

Catalog

    Article views (381) PDF downloads (8) Cited by(2)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return