ISSN 1004-4140
CN 11-3017/P
CHEN Mailin, LIU Yuliang, LI Xiaoting, QI Liping, SUN Yingshi. To Explore the Advantage of Gemstone CT Target Reconstruction in Displaying the Tissue Structure of Living Lung[J]. CT Theory and Applications, 2020, 29(1): 61-69. DOI: 10.15953/j.1004-4140.2020.29.01.08
Citation: CHEN Mailin, LIU Yuliang, LI Xiaoting, QI Liping, SUN Yingshi. To Explore the Advantage of Gemstone CT Target Reconstruction in Displaying the Tissue Structure of Living Lung[J]. CT Theory and Applications, 2020, 29(1): 61-69. DOI: 10.15953/j.1004-4140.2020.29.01.08

To Explore the Advantage of Gemstone CT Target Reconstruction in Displaying the Tissue Structure of Living Lung

More Information
  • Received Date: September 23, 2019
  • Available Online: November 10, 2021
  • Published Date: February 24, 2020
  • objective:to compare the image quality and the display of the structure of normal lung between lung CT targeted reconstruction (local small FOV thin layer CT imaging) and conventional lung CT. Methods:74 cases of subjects respectively routine pulmonary CT scan (5mm) and targeted reconstruction (FOV:20 cm, thickness:1.25mm). Two radiologists respectively determine normal lung CT imaging, targeted reconstruction image quality:pulmonary lobule structure, pulmonary vessels and bronchial branches display (grade 1~4) and judge the strength of confidence. The targeted reconstruction with 1.25-mm sections and small FOV showed more was used as the gold standard. and further determine the sensitivity of targeted reconstruction and conventional lung CT scan imaging (5mm), the consistency between two observers to make Kappa test. Results:Level 1 and 2 image quality of conventional lung CT scan and targeted reconstruction showed no significant statistical differences. Level 3 and level 4 image quality, targeted reconstruction is superior to the conventional lung CT scan, the differences between two observers was statistically significant (P<0.05); According to the targeted reconstruction imaging, Conventional pulmonary CT scan imaging (5mm) Level 3 image's sensitivity was 97.1%, 98.6%, respectively; Level 4 image's sensitivity was 80.8%, 85.3% respectively. And diagnostic confidence level increased significantly (P<0.05). Image quality judgment has a good consistency for targeted reconstruction, conventional lung CT between two observers (k=0.717, 0.746). Conclusion:Compared with conventional CT images, targeted reconstruction images can increase the normal display rate of pulmonary microstructure, the confidence of the judgment.
  • Related Articles

    [1]YANG Feng. The Application Value of Spiral CT in Diagnosis and Dynamic Observation of Pulmonary Laceration[J]. CT Theory and Applications, 2018, 27(2): 263-268. DOI: 10.15953/j.1004-4140.2018.27.02.15
    [2]XIONG Shan, XU Lei, CHENG Jian-min, CHEN Bo, ZHENG Li, DAI Ting-ting, LIU Si-bin, HUANG Yuan-yi. Application of Iterative Reconstruction in Low-dose Chest CT Scans of Preschool Children[J]. CT Theory and Applications, 2017, 26(6): 729-736. DOI: 10.15953/j.1004-4140.2017.26.06.09
    [3]SUN Chong-peng, YAN Cheng-gong, LI Xin-chun, HE Jian-xun, CENG Qing-si. CT Findings of Pulmonary Lymphomatoid Granulomatosis[J]. CT Theory and Applications, 2017, 26(3): 335-342. DOI: 10.15953/j.1004-4140.2017.26.03.10
    [4]MA Yu-tian, LIU Jun-biao, NIU Geng, ZHAO Wei-xia, HAN Li. Research on the Preparation and Performance of Tungsten-diamond Transmission Target for Microfoucs X-ray Source[J]. CT Theory and Applications, 2017, 26(2): 189-194. DOI: 10.15953/j.1004-4140.2017.26.02.07
    [5]GUAN Li-jun, JIA Guang-zhi, ZHANG Chun-long, LI Xiao-guang. Analysis of Complications and Treatment of CT-guided Radiofrequency Ablation of Lung Tumours[J]. CT Theory and Applications, 2016, 25(6): 687-694. DOI: 10.15953/j.1004-4140.2016.25.06.09
    [6]HUANG Yao-qu, LI Jun-hong, LIANG Zhen-hua. CT Findings and Dynamic Analysis of Pulmonary Laceration[J]. CT Theory and Applications, 2013, 22(2): 303-308.
    [7]CHEN Yin-yin, CHEN Wei-tang, CHEN Ying-feng. CT Findings and Cause Analysis of Tuberculosis Nodules or Masses Misdiagnosed as Lung Cancer[J]. CT Theory and Applications, 2012, 21(2): 297-303.
    [8]LI Cheng-quan, LI Zheng, LI Chen, YU Ai-min. Investigation of Image Reconstruction Algorithms for In-line X-ray Phase Contrast Tomography[J]. CT Theory and Applications, 2007, 16(2): 1-7.
    [9]HUANG Fu-qi, CHEN Qin, CHEN Yi-hui. Three Dimension Computerized Tomography Configuration of Lung Nodus:Its Clinical Application[J]. CT Theory and Applications, 2003, 12(1): 43-46.
    [10]Li Zhongxi, Xu Kai, Wang Xu, Zhang Longzhen. CT Analysis of Radiation-induced Pulmonary Injury[J]. CT Theory and Applications, 2001, 10(1): 21-24.
  • Cited by

    Periodical cited type(2)

    1. 马志强,赵永超,李志鹏. 螺旋CT靶重建在独立性肺结节定性诊断中的应用价值. 深圳中西医结合杂志. 2024(08): 72-75 .
    2. 马硕,杜华阳,宋兰,隋昕,张二宁,秦瑞遥,宋伟,方捷. 不同重建矩阵对薄层胸部CT图像质量及磨玻璃结节显示的影响研究. 中国医学装备. 2022(07): 30-34 .

    Other cited types(1)

Catalog

    Article views (461) PDF downloads (13) Cited by(3)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return