ISSN 1004-4140
CN 11-3017/P
LI Yanju, LIU Xiaoxing, LIANG Shanshan, RAN Caihong, NNDA Zhuoma. Guidance Value of MSCT in the Diagnosis and Clinical Treatment of GST[J]. CT Theory and Applications, 2020, 29(1): 71-77. DOI: 10.15953/j.1004-4140.2020.29.01.09
Citation: LI Yanju, LIU Xiaoxing, LIANG Shanshan, RAN Caihong, NNDA Zhuoma. Guidance Value of MSCT in the Diagnosis and Clinical Treatment of GST[J]. CT Theory and Applications, 2020, 29(1): 71-77. DOI: 10.15953/j.1004-4140.2020.29.01.09

Guidance Value of MSCT in the Diagnosis and Clinical Treatment of GST

More Information
  • Received Date: July 09, 2019
  • Available Online: November 10, 2021
  • Published Date: February 24, 2020
  • Objective:To analyze the guidance value of multi-slice spiral computed tomography (MSCT) in the diagnosis and clinical treatment of gastric stromal tumor (GST). Method:The clinical data of 56 patients with gastric stromal tumor admitted to our hospital from January 2018 to February 2019 were collected. The clinical data of patients were collected to evaluate the pathological risk of patients. The differences in MSCT images between patients with different pathological risks were analyzed, and the diagnostic accuracy of MSCT for GST was calculated. Results:Among the 56 patients, 11 patients (19.64%) had very low pathological risk, 18 patients (32.14%) had low risk, 14 patients (25.00%) had moderate risk, and 13 patients (23.21%) had high risk. There was no significant difference in the density of MSCT, the presence or absence of necrosis/ulcer in the tumor, the difference value of degree of of arteriovenous enhancement, the presence or absence of the intravascular and peritumoral vessels, and the pathological risk (P>0.05). There was a significant difference in peritumoral fat space, enhancement mode and pathological risk (P<0.05). Taking pathological biopsy as a control, the number of accurate diagnosis of GST by MSCT was 53 cases, and the diagnostic accuracy was 94.64%. Three cases were misdiagnosed as gastric cancer, and the misdiagnosis rate was 5.45%. Conclusion:MSCT has a high diagnostic accuracy for GST, which can effectively display the characteristics of GST images with different pathological risks, and can provide reliable imaging information for clinical operations.
  • Related Articles

    [1]MIAO Na, QI Xuhong, DU Changyue, CHEN Shiguang, BI Dongmei, WEN Zhiyong. The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast[J]. CT Theory and Applications, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
    [2]WU Yan-chun, LIU Yao. Clinical Value of CT、MRI in the Diagnosis of Cystic Lesions of the Pancreas and the Pathological Analysis[J]. CT Theory and Applications, 2017, 26(5): 591-597. DOI: 10.15953/j.1004-4140.2017.26.05.08
    [3]XU Guan-zhen, ZOU Wen-yuan, SHI Lei, LIU Yue, CENG Lei, JI Tao-tao, LI Jing-jing, LIN Hua. The Clinical Diagnostic Value of MSCT in Primary Epiploic Appendagitis[J]. CT Theory and Applications, 2017, 26(4): 525-532. DOI: 10.15953/j.1004-4140.2017.26.04.16
    [4]XU Guan-zhen, TONG Cheng-wen, LAN Shan, WANG Lin-lin, LIU Yuan-yuan, LUO Xiao-qin, ZHANG Zi-li, ZOU Wen-yuan. The Diagnosis Value of Solitay Plasmacytoma in Spine Using Multi-slice Computed Tomography[J]. CT Theory and Applications, 2016, 25(2): 183-188. DOI: 10.15953/j.1004-4140.2016.25.02.08
    [5]ZHANG Zhi-guo, YU Qing-wen, SUN Qing-ju, ZHOU Su-ning. Clinical Diagnosis Value of 128-slice Spisal CT compared to X-ray CAG[J]. CT Theory and Applications, 2014, 23(5): 835-841.
    [6]ZHANG Hai-bo, HU Xi-yao, FU Chuan-ming, XU Lin, WANG Kai-hua. MSCT One-stop Recombination in Lumbar Disease Diagnosis Application Value[J]. CT Theory and Applications, 2012, 21(1): 81-88.
    [7]XU Guan-zhen, FU Chuan-ming, GONG Xiao-hong, CHEN Ping-you. The Comparison of Clinical Diagnosis Value about Sacral Fracture with MSCT and DR[J]. CT Theory and Applications, 2011, 20(2): 269-276.
    [8]FU Chuan-ming, CHEN Yi-jia, CHEN Xue-qiang, CHEN Lun-gang, ZOU Jian-hua, WU Wen-qiang. MSCT and X-ray: The Comparison of Clinical Value in the Diagnosis of Lumbar Spondylolisthesis[J]. CT Theory and Applications, 2010, 19(3): 67-73.
    [9]GAO Yun, HU Dao-yu, LI Zhen, MENG Ling-shan, ZHANG Wei-min. Guidance of Multislice Helical Computed-tomography Angiography of Abdomen in Interventional Operation of Liver Tumors[J]. CT Theory and Applications, 2007, 16(2): 75-79.
    [10]Hu Bing. CT Diagnosis of Renal Trauma and Its Clinic Value[J]. CT Theory and Applications, 2000, 9(1): 35-36.
  • Cited by

    Periodical cited type(0)

    Other cited types(1)

Catalog

    Article views (322) PDF downloads (8) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return