ISSN 1004-4140
CN 11-3017/P
ZANG Yanwei, ZHANG Jing. Diagnostic Value of CT Coronary Angiography Combined with MMP-10 and F-ABP in Myocardial Infarction[J]. CT Theory and Applications, 2020, 29(4): 481-487. DOI: 10.15953/j.1004-4140.2020.29.04.11
Citation: ZANG Yanwei, ZHANG Jing. Diagnostic Value of CT Coronary Angiography Combined with MMP-10 and F-ABP in Myocardial Infarction[J]. CT Theory and Applications, 2020, 29(4): 481-487. DOI: 10.15953/j.1004-4140.2020.29.04.11

Diagnostic Value of CT Coronary Angiography Combined with MMP-10 and F-ABP in Myocardial Infarction

More Information
  • Received Date: November 27, 2019
  • Available Online: November 10, 2021
  • Objective:To explore the diagnostic efficacy of dual source CT coronary angiography combined with serum MMP-10 and F-ABP levels(combined diagnosis) for new acute myocardial infarction(AMI). Methods:62 patients with AMI and 60 patients with non AMI cardiovascular disease were enrolled in the Department of Cardiology of our hospital. The levels of MMP-10 and F-ABP were detected by dual source CT coronary angiography. Based on the results of coronary angiography, the diagnostic efficacy of dual source CT coronary angiography combined with serum MMP-10 and f-abp was analyzed. Results:the levels of MMP-10 and F-ABP in the case group were higher than those in the control group[(8.32 ±0.26) μg/L vs(5.95 ±0.39) μg/L,(8.59 ±2.34) μg/L vs(4.21 ±1.25) μg/L, P < 0.05]. 56 cases of AMI were correctly diagnosed by dual source CT. ROC analysis showed that dual source CT, serum MMP-10, F-ABP and AUC were 0.910, 0.843 and 0.772 respectively. The sensitivity and specificity of dual source CT were 90.32% and 88.33% respectively. The sensitivity and specificity of MMP-10 in the diagnosis of AMI were 79.03% and 83.33% respectively. The sensitivity and specificity of F-ABP in the diagnosis of AMI were 83.87% and 80.00% respectively. The sensitivity and specificity were 98.39% and 100.00%, respectively. Conclusion:dual source CT coronary angiography, serum MMP-10, F-ABP levels have certain diagnostic efficacy for new AMI, the combined diagnosis is closer to the real results, with higher accuracy.
  • Related Articles

    [1]WANG Ke, JI Hanying, HUANG Xiaoqi, PAN Juan. Diagnostic Efficacy of Quantitative Computed Tomography in CTD-ILA/ILD[J]. CT Theory and Applications, 2025, 34(4): 611-620. DOI: 10.15953/j.ctta.2025.034
    [2]JIA Sulan, DU Jingbo, SU Xiaohua. The Diagnostic Efficacy of Version 2018 LI-RADS for Hepatocellular Carcinoma on Enhanced Magnetic Resonance Imaging[J]. CT Theory and Applications, 2024, 33(1): 35-41. DOI: 10.15953/j.ctta.2023.073
    [3]E Tianjiao, FENG Feng, XU Haifei. Exploratory Research on the Influence of MR Image Quality of Bladder Cancer and Diagnostic Efficacy Using Two Preparation Methods[J]. CT Theory and Applications, 2023, 32(4): 501-508. DOI: 10.15953/j.ctta.2022.209
    [4]LIU Na, ZHAO Zhengkai, ZOU Jiayu, LI Yi, LIU Jian. Evaluation of Detection and Diagnostic Efficiency of Pulmonary Nodules by Chest CT Based on Artificial Intelligence[J]. CT Theory and Applications, 2021, 30(6): 709-715. DOI: 10.15953/j.1004-4140.2021.30.06.06
    [5]LIU Li, JIN Mei, LI Xin, YAN Xiaoguang, CHEN Tong, KANG Xin, CHEN Wenjing, GAO Xiaolong. Research on the Correlation between Diagnostic Efficacy and Pathological Type of Dual-energy CT in Thyroid Nodules[J]. CT Theory and Applications, 2021, 30(5): 611-618. DOI: 10.15953/j.1004-4140.2021.30.05.09
    [6]WEN Deying, PAN Xuelin, YAO Hui, LI Jijie, DENG Qiao, TANG Lu, WU Xi, SUN Jiayu. To Explore the Effect of CT Scan Dose on the Efficacy of Artificial Intelligence in Detecting Lung Nodules[J]. CT Theory and Applications, 2021, 30(4): 455-465. DOI: 10.15953/j.1004-4140.2021.30.04.06
    [7]XUE Ying-yue, SHAO Qing, CAI Man-man. Ultrasound Elastic Strain Rate Values in the Differentiation of Mastitis and Breast Cancer[J]. CT Theory and Applications, 2018, 27(3): 379-385. DOI: 10.15953/j.1004-4140.2018.27.03.11
    [8]DONG Jian, YANG Lei, YAN Nuan, WEN Jing, ZHANG Chun-yan, CHEN Xiao-bo, WEN Ting-guo, WANG Ren-gui. Coronary Artery CT Angiography in Coronary-pulmonary Fistula:A Retrospective Study[J]. CT Theory and Applications, 2017, 26(4): 519-524. DOI: 10.15953/j.1004-4140.2017.26.04.15
    [9]CAO Yu, ZHANG Yong-xian. Comparison of Multi-slice Spiral CT Imaging for Cardiac Coronary Arteries with Different Radiation Doses[J]. CT Theory and Applications, 2016, 25(1): 95-101. DOI: 10.15953/j.1004-4140.2016.25.01.12
    [10]ZHANG Chao-liang, GUAN Yu-bao, LIN Han-fei, CHEN Huai, ZENG Qing-si. Application Study of Low-dose 128-Slice Spiral CT Coronary Artery Angiography[J]. CT Theory and Applications, 2012, 21(4): 753-759.
  • Cited by

    Periodical cited type(2)

    1. 罗薇,张晶,李茜. DECT心肌灌注成像联合血清ANXA1诊断心肌梗死的研究. 影像科学与光化学. 2022(05): 1133-1137 .
    2. 申金晶,焦芸静,张丹,孟华. 心脏超声与冠脉造影检测心肌梗死患者心脏结构与功能病变的价值. 华夏医学. 2022(05): 69-73 .

    Other cited types(1)

Catalog

    Article views (336) PDF downloads (11) Cited by(3)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return