ISSN 1004-4140
CN 11-3017/P
CHANG Xin, DENG Gang, WANG Xu, XU Tongjiang, YIN Xiaoming. Application of Different Settings of 64-slice Spiral CT in Screening of Novel Coronavirusinfected Pneumonia[J]. CT Theory and Applications, 2020, 29(5): 543-550. DOI: 10.15953/j.1004-4140.2020.29.05.04
Citation: CHANG Xin, DENG Gang, WANG Xu, XU Tongjiang, YIN Xiaoming. Application of Different Settings of 64-slice Spiral CT in Screening of Novel Coronavirusinfected Pneumonia[J]. CT Theory and Applications, 2020, 29(5): 543-550. DOI: 10.15953/j.1004-4140.2020.29.05.04

Application of Different Settings of 64-slice Spiral CT in Screening of Novel Coronavirusinfected Pneumonia

More Information
  • Received Date: March 25, 2020
  • Available Online: November 10, 2021
  • Objective:To investigate the feasibility of reducing the radiation dose and scanning time of patients with novel coronavirus pneumonia by setting the parameters of 64-slice spiral CT. Methods:Prospective selection of patients who needed to be screened for novel coronavirus pneumonia was randomly divided into a large pitch group and a control group according to the scan time, with 16 cases in each group. The large-pitch group chose 1.375:1, and the control group chose 0.984:1.The image quality of lung markings, bronchus, and mediastinal structure, objective data of thoracic aorta, erector spinae, bilateral lung parenchyma, and radiation dose were evaluated and analyzed. Results:32 cases of images meet the requirements of imaging diagnosis. The artifact and lung markings scores were significantly different(P<0.05). The CT values of the right lung were-804.62 ±45.43 and(-852.12 ±28.13) HU, and the CT values of the left lung were(-808.13 ±37.74) HU and(-858.77 ± 19.95) HU, demonstrates statistically significant(P<0.05). The scanning time of the two groups was(2.14 ±0.15) s and(3.14 ±0.28) s, respectively, which was statistically significant(P<0.05). The volume CT dose index(CTDIvol) recorded by the two groups was(7.88 ±0.89) HU and(11.17 ±1.08) HU, and the dose length product(DLP) was(279.14 ±36.33) HU and(387.25 ±47.86) HU. Both were statistically significant(P<0.05). The effective dose(ED) were(3.91 ±0.51) HU and(5.42 ±0.67) HU, respectively, with statistical significance(P<0.05). Conclusion:The use of large-pitch scanning in CT screening of patients with novel coronavirus pneumonia can reduce the radiation dose, significantly shorten the scan time, and reduce the radiation dose received by patients and the risk of infection by radiation technicians without affecting the diagnosis of lesions. It as practical significance, and needs to be further promoted and verified.
  • Related Articles

    [1]HU Yanjun, WEI Xuan, ZHANG Yu, TIAN Xin, WANG Likun, JIANG Guilian, NIU Yantao. Effect of External Foreign Bodies on Patient Radiation Dose in Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.103
    [2]QI Rongfei, JIANG Wenlong, HAO Yunyun, YANG Liusha, CHANG Yingjuan, WU Zhibin. A Study of Image Quality and Radiation Dose in Lower Extremity Computed Tomography Angiography Using Caudo-cranial Flash Scanning[J]. CT Theory and Applications, 2025, 34(3): 385-391. DOI: 10.15953/j.ctta.2024.210
    [3]XIE Ruigang, WANG Siyan, AN Hengbin, SU Tao, SUN Minghua. Impact of Electrocardiogram Gating Technology on Radiation Dose in Dual-source Computed Tomography High Pitch Spiral Scanning Using a Phantom[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.300
    [4]WANG Chensi, HONG Yao, FANG Huimin, DING Xuelu, YANG Yifan, TIAN Xiangbao, CHEN Wenjing, WANG Yongsheng. Based on the Effect of Different Pitches on Neck CTA Radiation Dose and Image Quality under Automatic Tube Current Modulation Technology[J]. CT Theory and Applications, 2024, 33(3): 309-315. DOI: 10.15953/j.ctta.2023.148
    [5]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [6]LIU Wangyang, SUN Cunjie, ZHAO Honglan, WANG Xiuling. Study on Evaluation Method of Radiation Dose of Patients in TACE of IVR-CT[J]. CT Theory and Applications, 2019, 28(6): 653-658. DOI: 10.15953/j.1004-4140.2019.28.06.02
    [7]WU De-hong, CHEN Shao-bo, FU Chuan-ming, XU Lin, CHEN Lun-gang, YU Guang-ju. Value of Automatic Tube Current Modulation Techniques to Reducing the Radiation Dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18
    [8]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [9]FANG Lin, LI Liang. Application Progress of Adaptive Statistical Iterative Reconstruction in Reducing Radiation Dose[J]. CT Theory and Applications, 2013, 22(2): 207-213.
    [10]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.

Catalog

    Article views (498) PDF downloads (9) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return