ZHANG Xufang, WANG Haipeng, LI Jun, MA Jie, LI Jianli, YANG Yushuang, HOU Liangliang, LI Li. Study on the Microstructure of Ancient Pig Teeth Based on Micro-CT and Data-constrained Modeling[J]. CT Theory and Applications, 2020, 29(6): 677-685. DOI: 10.15953/j.1004-4140.2020.29.06.05
Citation:
ZHANG Xufang, WANG Haipeng, LI Jun, MA Jie, LI Jianli, YANG Yushuang, HOU Liangliang, LI Li. Study on the Microstructure of Ancient Pig Teeth Based on Micro-CT and Data-constrained Modeling[J]. CT Theory and Applications, 2020, 29(6): 677-685. DOI: 10.15953/j.1004-4140.2020.29.06.05
ZHANG Xufang, WANG Haipeng, LI Jun, MA Jie, LI Jianli, YANG Yushuang, HOU Liangliang, LI Li. Study on the Microstructure of Ancient Pig Teeth Based on Micro-CT and Data-constrained Modeling[J]. CT Theory and Applications, 2020, 29(6): 677-685. DOI: 10.15953/j.1004-4140.2020.29.06.05
Citation:
ZHANG Xufang, WANG Haipeng, LI Jun, MA Jie, LI Jianli, YANG Yushuang, HOU Liangliang, LI Li. Study on the Microstructure of Ancient Pig Teeth Based on Micro-CT and Data-constrained Modeling[J]. CT Theory and Applications, 2020, 29(6): 677-685. DOI: 10.15953/j.1004-4140.2020.29.06.05
1. a). Institute of Theoretical Physics and Department of Physics;b). College of Physics and Electronics Engineering;c). College of History and Culture;d). State Key Laboratory of Quantum Optics and Quantum Optic Devices, Institute of Laser Spectroscopy, College of Physics and Electronic Engineering, Shanxi University, Taiyuan 030006, China;
2. CSIRO, Private Bag 10, Clayton, Victoria 3169, Australia
In this paper,the jaw bone and teeth of an ancient pig unearthed from a historic site were imaged using a micro-CT.The three-dimensional(3D) structure of the sample was quantitatively calculated based on data-constrained modeling(DCM).The multi-scale structure of the sample including those smaller than CT imaging resolution size was obtained.The multi-scale connectivity of pore and high X-ray absorption compositions in the sample were calculated respectively.The 3D distribution form of pore and high X-ray absorption compositions clusters was obtained.Compared with common image threshold segmentation method,DCM efficiently reduces the influence of partial volume effect on image analysis.The results of this study provide a data basis for the internal morphological measurement and structural analysis of archaeological samples.The method presented in this paper can be applied to the digital modeling and archiving of archaeological samples.