ISSN 1004-4140
CN 11-3017/P
Volume 29 Issue 6
Dec.  2020
Turn off MathJax
Article Contents
LI Sichun, LI Zhihui, ZHANG Yaping. Predictive Value of CT Angiography Combined with Blood Lipid Level in Diabetes Mellitus with Coronary Artery Disease[J]. CT Theory and Applications, 2020, 29(6): 711-717. DOI: 10.15953/j.1004-4140.2020.29.06.09
Citation: LI Sichun, LI Zhihui, ZHANG Yaping. Predictive Value of CT Angiography Combined with Blood Lipid Level in Diabetes Mellitus with Coronary Artery Disease[J]. CT Theory and Applications, 2020, 29(6): 711-717. DOI: 10.15953/j.1004-4140.2020.29.06.09

Predictive Value of CT Angiography Combined with Blood Lipid Level in Diabetes Mellitus with Coronary Artery Disease

More Information
  • Received Date: February 19, 2020
  • Available Online: November 10, 2021
  • Objective:To explore the value of CT angiography(CTA) combined with blood lipid level in the diagnosis of diabetes mellitus complicated with coronary artery disease. Methods:The clinical data of 73 patients with type 2 diabetes mellitus(T2DM) were retrospectively analyzed, including 38 patients with coronary artery disease(T2DM-CHD group) and 35 patients without coronary artery disease(T2DM group). All patients were routinely tested for blood lipid level, and coronary CTA was performed. Based on the results of CAG, the value of CTA combined with blood lipid level in predicting coronary artery lesions in patients with T2DM was analyzed. Result:TC, TG and LDL-C increased gradually with the occurrence and severity of coronary artery disease(P<0.05), while HDL-C decreased gradually(P<0.05). CTA had a high consistency with CAG in the diagnosis of coronary artery lesions in patients with T2DM(Kappa value=0.752, P=0.000). The sensitivity, specificity, positive predictive value and negative predictive value of combined lipid and CTA examination were significantly higher than those of single lipid and CTA diagnosis, which were 92.31%, 95.15%, 95.34% and 96.37% respectively. Conclusion:CTA detection is helpful to predict the occurrence and severity of CHD, and combined with blood lipid level can improve the detection efficiency of coronary artery lesions in patients with T2DM.
  • Cited by

    Periodical cited type(3)

    1. 郭杰,蔡爱龙,王少宇,郑治中,李磊,闫镔. 光子计数探测器投影数据噪声的p-范分布统计分析. 光学学报. 2024(03): 102-110 .
    2. 杨光,高嘉保,韩瑞. 基于深度学习建立模型去除工业CT伪影的技术研究. 无损探伤. 2023(03): 18-22 .
    3. 丰川. 多层螺旋CT双低剂量扫描在冠状动脉血管成像诊断冠心病中的应用价值. 影像研究与医学应用. 2023(13): 87-89 .

    Other cited types(2)

Catalog

    Article views (297) PDF downloads (8) Cited by(5)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return