ISSN 1004-4140
CN 11-3017/P
BU Yulian, ZHANG Huan, PAN Zilai, YANG Wenjie, CHEN Kemin, YAN Fuhua. Clinical Application of Dual Energy Spectral CT in Evaluating Cardiac Function in Patients with Ischemic Heart Disease[J]. CT Theory and Applications, 2021, 30(3): 354-360. DOI: 10.15953/j.1004-4140.2021.30.03.09
Citation: BU Yulian, ZHANG Huan, PAN Zilai, YANG Wenjie, CHEN Kemin, YAN Fuhua. Clinical Application of Dual Energy Spectral CT in Evaluating Cardiac Function in Patients with Ischemic Heart Disease[J]. CT Theory and Applications, 2021, 30(3): 354-360. DOI: 10.15953/j.1004-4140.2021.30.03.09

Clinical Application of Dual Energy Spectral CT in Evaluating Cardiac Function in Patients with Ischemic Heart Disease

More Information
  • Received Date: February 21, 2021
  • Available Online: November 05, 2021
  • Objective: To study the clinical application value of spectral CT in evaluating cardiac function in patients with ischemic heart disease,so as to provide a novel and reliable imaging diagnostic system for cardiac function. Methods: 40 patients with ischemic heart disease were scanned with the high resolution density coronary CT angiography(HDCTA) and the gemstone spectral imaging(GSI) modes. In addition, all cases had the Cardiac MRI scan within a week. Obtained monochromatic images(40 ~ 140 ke V) and the iodine-based material-decomposition images from Spectral Analysis Software. The k value and the iodine concentration of the normal myocardial and ischemic myocardium were obtained respectively. Software automatically calculate the EDV, ESV, EF of left ventricular. The results were compared with MRI evaluation results. Results: The k value and the iodine concentration of normal myocardial were higher than the ischemic myocardium. Ischemic myocardium detected on Spectral CT showed the corresponding segment wall motion degree decreased in cine-MRI imaging. There were good correlation and consistency between the EDV, ESV, EF calculated by HDCTA and the results calculated by MRI. Conclusions: Dual Energy Spectral CT combined with cardiac function analysis software can quantitatively evaluate myocardial blood supply, effectively evaluate cardiac function in patients with ischemic heart disease.
  • Related Articles

    [1]HU Yanjun, WEI Xuan, ZHANG Yu, TIAN Xin, WANG Likun, JIANG Guilian, NIU Yantao. Effect of External Foreign Bodies on Patient Radiation Dose in Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.103
    [2]LI Zhen, WANG Ziwei, YU Guangfu, LIAO Kai. Deep Learning Reconstruction Algorithm Combined with “Double Low” Dose for Liver CT Enhancement[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.306
    [3]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [4]LIU Wangyang, SUN Cunjie, ZHAO Honglan, WANG Xiuling. Study on Evaluation Method of Radiation Dose of Patients in TACE of IVR-CT[J]. CT Theory and Applications, 2019, 28(6): 653-658. DOI: 10.15953/j.1004-4140.2019.28.06.02
    [5]WU De-hong, CHEN Shao-bo, FU Chuan-ming, XU Lin, CHEN Lun-gang, YU Guang-ju. Value of Automatic Tube Current Modulation Techniques to Reducing the Radiation Dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18
    [6]CHANG Xin, WANG Xu, FENG Chen-lu. The Effect of Axial and Spiral Scan Mode in Emergency Head CT on Image Quality and Radiation Dosage[J]. CT Theory and Applications, 2015, 24(1): 117-122. DOI: 10.15953/j.1004-4140.2015.24.01.14
    [7]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [8]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [9]FANG Lin, LI Liang. Application Progress of Adaptive Statistical Iterative Reconstruction in Reducing Radiation Dose[J]. CT Theory and Applications, 2013, 22(2): 207-213.
    [10]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.

Catalog

    Article views (247) PDF downloads (15) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return