ISSN 1004-4140
CN 11-3017/P
YANG Li, ZHANG Bao-jin, WEN Peng-fei, ZHANG Ru-wei, XUE Hua, GU Yuan. Study on Data Processing of Sub-bottom Profile Based on the Chirp Signal in Order to Distinguish Thin Layer[J]. CT Theory and Applications, 2016, 25(6): 653-660. DOI: 10.15953/j.1004-4140.2016.25.06.05
Citation: YANG Li, ZHANG Bao-jin, WEN Peng-fei, ZHANG Ru-wei, XUE Hua, GU Yuan. Study on Data Processing of Sub-bottom Profile Based on the Chirp Signal in Order to Distinguish Thin Layer[J]. CT Theory and Applications, 2016, 25(6): 653-660. DOI: 10.15953/j.1004-4140.2016.25.06.05

Study on Data Processing of Sub-bottom Profile Based on the Chirp Signal in Order to Distinguish Thin Layer

More Information
  • Received Date: May 16, 2016
  • Available Online: December 04, 2022
  • Published Date: December 24, 2016
  • Sub-bottom profiler based on Chirp signal is widely used in the fields of engineering investigation, geological hazard assessment, gas hydrate investigation and deep sea resources exploration because of its high resolution. Due to the narrow bandwidth of the Chirp signal, the side lobe of cross-correlation result is serious. Conventional extraction envelope processing can suppress side lobe, but the resolution of the data is low. In this paper, the different theoretical models and the actual data are processed by the method of mutual correlation, extracting amplitude envelope and linear frequency extraction and their results are remarkable.
  • Related Articles

    [1]WANG Zhaoqi, LI Lin, WANG Bin, WANG Xuefeng, LI Lisheng. Application of Broadband Seismic Data Processing Technology in the Description of Natural Gas Hydrate Ore Body[J]. CT Theory and Applications, 2021, 30(5): 547-554. DOI: 10.15953/j.1004-4140.2021.30.05.02
    [2]YAN Xiaofei, WANG Rui, LI Yuqing, LI Wenwen. Application of the First Arrival Waves Automatic Extraction Transformation and Process Optimization in Cross-hole Elastic Wave CT[J]. CT Theory and Applications, 2019, 28(5): 559-568. DOI: 10.15953/j.1004-4140.2019.28.05.05
    [3]XU Yun-xia, WEN Peng-fei, ZHANG Ru-wei, ZHANG Bao-jin, XUE Hua. The Application of No-well Impedance Inversion in Xisha Area Hydrate Research[J]. CT Theory and Applications, 2017, 26(4): 425-434. DOI: 10.15953/j.1004-4140.2017.26.04.04
    [4]CHEN Si, LI Jing, LI Shi-gen, LI Shou-tao, CHEN Yun-bin, ZHANG Xiao-li. A Registration and Evaluation Algorithm for the Calibration of Point Extraction Precision Based on ICT Equipment[J]. CT Theory and Applications, 2016, 25(6): 671-678. DOI: 10.15953/j.1004-4140.2016.25.06.07
    [5]CUI Xu-ran, HUO Guo-dong, ZHENG Xiao-xue. Elastic Impedance Parameters Extraction Based on Accumulation Method[J]. CT Theory and Applications, 2015, 24(2): 177-189. DOI: 10.15953/j.1004-4140.2015.24.02.04
    [6]LI Ling, YE Hua-shan, YU Hou-qiang. Extraction of ROI from CT Liver Based on Entropy Image Segmention Algorithm[J]. CT Theory and Applications, 2012, 21(1): 53-60.
    [7]DING Fei, CHEN Zhi-qiang, HUANG Zhi-feng, ZHANG Li. Review on Refraction-Angle Extraction Methods in Diffraction Enhanced Imaging[J]. CT Theory and Applications, 2008, 17(3): 27-35.
    [8]PU Yi-bin, XING Li-li, WU Qing-bo, DENG You-sheng. The First Study on CT Experiment Way for Gas Hydrate[J]. CT Theory and Applications, 2005, 14(2): 54-62.
    [9]LUO Guo-cheng, ZHAO Yong-jie. Heart Contour fitting in PET Image Using Mathematical Morphology and Spline Model[J]. CT Theory and Applications, 2002, 11(3): 1-6.
    [10]Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.

Catalog

    Article views (392) PDF downloads (6) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return