ISSN 1004-4140
CN 11-3017/P
WU Wen-shu, WANG Zhe, SHI Yi-fan, ZHAO Zhan-shan, WEI Cun-feng, WEI Long. Noise Reduction for Low-dose CT Sinogram Based on PDE[J]. CT Theory and Applications, 2017, 26(2): 177-188. DOI: 10.15953/j.1004-4140.2017.26.02.06
Citation: WU Wen-shu, WANG Zhe, SHI Yi-fan, ZHAO Zhan-shan, WEI Cun-feng, WEI Long. Noise Reduction for Low-dose CT Sinogram Based on PDE[J]. CT Theory and Applications, 2017, 26(2): 177-188. DOI: 10.15953/j.1004-4140.2017.26.02.06

Noise Reduction for Low-dose CT Sinogram Based on PDE

More Information
  • Received Date: October 26, 2016
  • Available Online: November 27, 2022
  • With the wide application of medical imaging technology,the low-dose CT has become an inevitable tendency in medical CT because of the gradual awareness of scan dose.However,the reconstruction image degradation in low-dose CT will affect the medical diagnostic accuracy.In order to solve the problem above,a4-neighborhood partial differential equation based on anisotropic diffusion equation sinogram noise reduction is proposed.To get more effective at noise smoothing and features preserving,novel model defined a weight normalized gradient according to the control rate of relevant pixel values.Additionally,a time-varied diffusion function based on the regular rule of image feature is provided to be adaptive for the balance between noise removal and edge preservation.Numerical results and scan data of the breast model reveal that the novel method can achieve better reconstruction image quality.
  • Related Articles

    [1]WEI Yili, YANG Ziyuan, XIA Wenjun, WANG Tao, ZHANG Yi. Low-dose CT Denoising Based on Subspace Projection and Edge Enhancement[J]. CT Theory and Applications, 2022, 31(6): 721-729. DOI: 10.15953/j.ctta.2022.108
    [2]SI Youqiang, GUO Runhua, LI Mengru. Application of Optimal Noise Reduction Smooth Model Based on EMD and EEMD in Seismic Waves[J]. CT Theory and Applications, 2020, 29(1): 11-21. DOI: 10.15953/j.1004-4140.2020.29.01.02
    [3]Kaijie Lu, LIU Bao-dong, Hengyong Yu. On Dose Reduction and View Number in Computed Tomography[J]. CT Theory and Applications, 2015, 24(2): 169-176. DOI: 10.15953/j.1004-4140.2015.24.02.03
    [4]CHEN Yan-hua, YUAN Xia-bing, XIE Jin, LI Yi, XU Wei-dong, HU Wei, PAN Hua-su, YANG Yong-xin, YANG Yong. Parallel-beam Algorithm and its Application in Breast Panel-PET[J]. CT Theory and Applications, 2014, 23(6): 923-929.
    [5]LIU Wen-lei, RONG Jun-yan, GAO Peng, LIAO Qi-mei, LU Hong-bing. Sparse-view Reconstruction from Restored Low-dose CT Projections[J]. CT Theory and Applications, 2013, 22(3): 421-428.
    [6]ZHANG Dao-zhong, HUO Xiu-kun, LI Tao, ZHANG Wei. Base on Improved NL-Means Algorithm for Medical CT Image Denoising[J]. CT Theory and Applications, 2013, 22(2): 297-302.
    [7]CHENG Ying, GUAN Ji-tian, JIN Yang, GUO Yue-lin, ZHANG Yuan-fang. 64-MSCT Coronary Angiography with Reduction Radiation Dose[J]. CT Theory and Applications, 2009, 18(3): 91-95.
    [8]CHENG Ying, CAI Xin-qi, CHEN Jun-bin, JING Yang, GUAN Ji-tian. The Sinus Image of Reduction Dose in Children with Spiral CT[J]. CT Theory and Applications, 2009, 18(2): 79-82.
    [9]TANG Jie, ZHANG Li, XING Yu-xiang, CHEN Zhi-qiang. Investigations into Error Reduction Based FDK Algorithms[J]. CT Theory and Applications, 2006, 15(1): 66-72.
    [10]GUO Lü-can, ZHAO Jing. The Function of Geo-tomography for Disaster Reduction[J]. CT Theory and Applications, 2004, 13(2): 60-63.

Catalog

    Article views (481) PDF downloads (16) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return