CEN Ren-li, LI Jian-yu, XIA Ting-ting, LI Jing-xu, LIU Qin, HUANG Xiao-yan, LI Lin. The Application of Lower Tube Voltage and Fewer Contrast Agents for Hepatic Enhanced CT Scanning[J]. CT Theory and Applications, 2017, 26(3): 357-364. DOI: 10.15953/j.1004-4140.2017.26.03.13
Citation: CEN Ren-li, LI Jian-yu, XIA Ting-ting, LI Jing-xu, LIU Qin, HUANG Xiao-yan, LI Lin. The Application of Lower Tube Voltage and Fewer Contrast Agents for Hepatic Enhanced CT Scanning[J]. CT Theory and Applications, 2017, 26(3): 357-364. DOI: 10.15953/j.1004-4140.2017.26.03.13

The Application of Lower Tube Voltage and Fewer Contrast Agents for Hepatic Enhanced CT Scanning

More Information
  • Received Date: December 13, 2016
  • Available Online: November 27, 2022
  • Objective: To explore the feasibility of lower tube voltage (110kVp) and fewer contrast agent (1.0 mL/kg) for hepatic enhanced CT scanning. Methods: 116 cases of patients, BMI 〈 25, underwent hepatic enhanced CT scanning were randomly divided into two groups, 58 cases for each. Group A: tube voltage 110 kV, and contrast agent being iopamidol (300mgI/mL), total contrast agent 1.0mL/kg, using sinogram affirmed iterative reconstruction (SAFIRE). Group B: tube voltage 130 kV, and contrast agent being iopamidol (300mgl/mL), total contrast agent 1.2 mL/kg, using filtered back projection (FBP). Abdominal aorta CT value in aorta phase, portal vein CT value in portal vein phase and three-phase (aorta phase, portal vein phase, delay phase) of the right lobe were measured, then the contrast to noise ratio (CNR), signal to noise ratio (SNR), and effective radiation dose (ED) were recorded. All the images of the two groups were given subjective ratings, and the statistical analysis was made for all the above indicators between the two groups. Results: There were no significant difference in SNR and CNR between the two groups (P > 0.05, respectively). There were no significant difference in the hepatic parenchymal CT value of the right lobe in three-phase and the abdominal aorta CT value in arterial phase between the two groups (P > 0.05, respectively). The portal vein CT value of group A was lower than that in group B (P < 0.05, significantly). The total ED of three-phase in group A was (9.88 ±3.56) mSv, it was lower than group R, (13.91 ±4.71)mSv (P < 0.001, significantly). Compared with group B, the total contrast agent dose of group A was reduced by 17%. Conclusion: In hepatic enhanced CT scanning, when using lower tube voltage (110 kVp), fewer contrast dose (1.0 mL/kg), and simultaneous iterative reconstruction technique with 128 slice spiral CT, it can provide better image quality, and reduce the ED and iodine intake of the human body.
  • Related Articles

    [1]HU Yanjun, WEI Xuan, ZHANG Yu, TIAN Xin, WANG Likun, JIANG Guilian, NIU Yantao. Effect of External Foreign Bodies on Patient Radiation Dose in Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.103
    [2]LI Zhen, WANG Ziwei, YU Guangfu, LIAO Kai. Deep Learning Reconstruction Algorithm Combined with “Double Low” Dose for Liver CT Enhancement[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.306
    [3]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [4]LIU Wangyang, SUN Cunjie, ZHAO Honglan, WANG Xiuling. Study on Evaluation Method of Radiation Dose of Patients in TACE of IVR-CT[J]. CT Theory and Applications, 2019, 28(6): 653-658. DOI: 10.15953/j.1004-4140.2019.28.06.02
    [5]WU De-hong, CHEN Shao-bo, FU Chuan-ming, XU Lin, CHEN Lun-gang, YU Guang-ju. Value of Automatic Tube Current Modulation Techniques to Reducing the Radiation Dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18
    [6]CHANG Xin, WANG Xu, FENG Chen-lu. The Effect of Axial and Spiral Scan Mode in Emergency Head CT on Image Quality and Radiation Dosage[J]. CT Theory and Applications, 2015, 24(1): 117-122. DOI: 10.15953/j.1004-4140.2015.24.01.14
    [7]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [8]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [9]FANG Lin, LI Liang. Application Progress of Adaptive Statistical Iterative Reconstruction in Reducing Radiation Dose[J]. CT Theory and Applications, 2013, 22(2): 207-213.
    [10]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.
  • Cited by

    Periodical cited type(3)

    1. 欧阳乐川,岑人丽. 能谱CT单能量图在泌尿系CTU检查中的低对比剂量研究. 影像研究与医学应用. 2021(14): 91-92 .
    2. 吴伟红,李仁战,叶文海,施莹莹. 低辐射剂量联合SAFIRE迭代算法应用于甲状腺CT增强扫描的可行性分析. 全科医学临床与教育. 2021(07): 620-623 .
    3. 李文婷,叶俊. CT增强扫描药物应用分析. 中国生化药物杂志. 2017(09): 364-365 .

    Other cited types(0)

Catalog

    Article views (634) PDF downloads (6) Cited by(3)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return