Monte Carlo Simulation for a Dynamic Bowtie Filter with Cone-beam CT

Funds: 

The National Instrumentation Program of China (2013YQ030629).

The National Natural Science Foundation of China (61471070)

More Information
  • Received Date: March 21, 2018
  • Available Online: November 07, 2021
  • A pre-patient attenuator ("Bowtie filter" or "Bowtie") in X-ray computed tomography (CT) is used for reducing the radiation dose to patients and helping meet the detector dynamic range, and it also affects the CT image quality. Because a traditional static Bowtie filter is not optimal for modulating X-ray, we recently proposed a dynamic Bowtie filter for cone-beam CT, which could modulate X-ray more effectively. In this paper, we design and study the dynamic Bow-tie using Monte Carlo simulation. First, we establish a simulation frame, which contains a target phantom and a polychromatic source generated by a reflection target. Next, a design phantom is employed to help design the dynamic Bowtie for the target phantom. Finally, we obtain two phantom projections from two modes of filter:no Bowtie and the dynamic Bowtie. The results demonstrate that, under the action of the designed dynamic Bowtie, the X-ray dynamic range on detectors is highly compressed for the design phantom and the target phantom, which means that our methodology facilitate to uniform the photon flux. Moreover, with the uniformed photon flux, the radiation exposure suffered by tested objects reduces and the reconstructed image quality is improved.
  • Related Articles

    [1]XIA Jing-tao, WANG Qun-shu, LI Bin-kang, HEI Dong-wei, SHENG Liang, MA Ji-ming, WEI Fu-li, MA Ge. Simulation Study of Spherical Multilayer Object CT Reconstruction from Sparse Projection Data[J]. CT Theory and Applications, 2014, 23(2): 249-256.
    [2]LI Bin, ZHANG Yao-jun, ZHU Pei-ping, LI Bao-lei, MO Yang. A Fast Simulation Method for CT Projection Based on Bisection[J]. CT Theory and Applications, 2014, 23(1): 115-122.
    [3]WANG Ya-xiao, WEI Cun-feng, QUE Jie-min, SHU Yan-feng, CAO Da-quan, WANG Yan-fang, SUN Cui-li, SHI Rong-jian, WEI Long. Computer Simulation of Digital Projections-of-cuboid Object in CL System[J]. CT Theory and Applications, 2014, 23(1): 91-100.
    [4]WU He-zhen, LIU Zheng-yi. Simulation Study on Pulse Compression by Bi-phase Coded Excitation with Carrier Modulation[J]. CT Theory and Applications, 2013, 22(1): 41-51.
    [5]YANG Zhen-yu, LÜ Yang, ZHAO Jun. Analysis of Scattering in Triple-source Cone-beam CT Based on Monte Carlo Method[J]. CT Theory and Applications, 2012, 21(1): 1-9.
    [6]XU Jing-hua, ZHOU Ming, LIU Zhen. Simulation Study of Positron Emission Tomography Based on GATE[J]. CT Theory and Applications, 2010, 19(4): 53-59.
    [7]WU He-zhen, HE Tai-ming. Simulation Study on Coded Excitation in Rock Property Ultrasound Imaging[J]. CT Theory and Applications, 2010, 19(4): 45-52.
    [8]LIU Yang, YOU Yong, LIU Yi-bao, ZHU Jia-shan. The Simulation and Study on the Protection Lead tin of TH-PPL CT[J]. CT Theory and Applications, 2010, 19(1): 48-55.
    [9]WANG Ge, Seung WookLee. Grangeat-Type and Katsevich-Type Algorithms for Cone-Beam CT[J]. CT Theory and Applications, 2003, 12(2): 45-55.
    [10]Ge Wang. Revisit to Derivative-Free Noncircular Fan-Beam Reconstruction - Responses to "iscussions on a Noncircular Fan-Beam Reconstruction Formula"by Huang, et al.[J]. CT Theory and Applications, 2003, 12(2): 39-44.

Catalog

    Article views (719) PDF downloads (31) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return