ISSN 1004-4140
CN 11-3017/P
LIU Min, LIN Yisheng, WANG Fangjun, LI Weihao, LIU Qiong, BAI Chenhui. Correlation of Image Quality and Angiographic Parameters in Two Groups of Angiocatheter by Hepatocellular Carcinoma DSA[J]. CT Theory and Applications, 2019, 28(3): 339-346. DOI: 10.15953/j.1004-4140.2019.28.03.07
Citation: LIU Min, LIN Yisheng, WANG Fangjun, LI Weihao, LIU Qiong, BAI Chenhui. Correlation of Image Quality and Angiographic Parameters in Two Groups of Angiocatheter by Hepatocellular Carcinoma DSA[J]. CT Theory and Applications, 2019, 28(3): 339-346. DOI: 10.15953/j.1004-4140.2019.28.03.07

Correlation of Image Quality and Angiographic Parameters in Two Groups of Angiocatheter by Hepatocellular Carcinoma DSA

More Information
  • Received Date: March 21, 2019
  • Available Online: November 05, 2021
  • Objective: To discuss the image quality of HCC based on the angiographic parameters of two types of angiocatheter, i.e. COOK MEDICAL RH angiocatheter and TERUMO MEDICAL RH angiocatheter. Methods: 40 cases (23 males, 17 females) of TACE in the First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine from June 2018 to January 2019 were selected. Patients ranged from 30 to 75 years with an average age of 56.3 and were all diagnosed with HCC. The actual imaging pressure of celiac trunk and superior mesenteric artery angiography in two groups of patients was analyzed and the image quality was evaluated under the same parameter settings, machinery and image post processing software with 20 cases using COOK MEDICAL RH angiocatheter (the COOK group) and 20 cases using TERUMO MEDICAL RH angiocatheter (the TERUMO group). Results: Among 340 angiography images of 40 cases, 36 cases showed good image quality with 16 from the COOK group and 20 from the TERUMO group, 4 cases showed poor image quality with all from the COOK group. The data was processed and analyzed with SPSS 25.0 software. The mean value of actual pressure of celiac trunk angiography was 107.6 PSI in the COOK group and 93.1 PSI in the TERUMO group, the difference was statistically significant (P<0.05), while that of the superior mesenteric artery angiography was 101.4 PSI in the COOK group and 88.9 PSI in the TERUMO group, the difference was statistically significant (P<0.05). Conclusion: Appropriate pressure should be chosen according to different angiocatheters in the selection of angiographic parameters. Lower pressure is advised in the case of TERUMO MEDICAL RH angiocatheter for good image quality.
  • Related Articles

    [1]WANG Yongsheng, YANG Leiqing, YANG Yifan, PEI Qingxia, WANG Chensi, LU Mengyun, HE Junlin, CHEN Wenjing, TIAN Xiangbao. The Effect of Different Trigger Thresholds on the Quality of Pulmonary Artery CT Angiography Images[J]. CT Theory and Applications, 2024, 33(2): 175-181. DOI: 10.15953/j.ctta.2023.121
    [2]WANG Yongsheng, ZHANG Pengyu, LI Fangzhong, WANG Zhenghua, LU Mengyun, CHEN Lei, HE Junlin, CHEN Wenjing. Study on the Influence of Head and Neck CTA Image Quality under Different Tube Voltages[J]. CT Theory and Applications, 2022, 31(5): 631-638. DOI: 10.15953/j.ctta.2022.026
    [3]LIU Fangtao, LIU Heshi, CHEN Yong, JIANG Jiang, WANG Lingyun, DONG Haipeng, ZHANG Yong, ZHANG Xuan, KONG Deyan, CHANG Rui. Image Quality Assessment for Deep Learning Image Reconstruction Algorithm: A Phantom Study[J]. CT Theory and Applications, 2022, 31(3): 351-356. DOI: 10.15953/j.ctta.2021.061
    [4]FANG Shu, CHEN Linyu, CHEN Yong, DONG Haipeng, WANG Lan, MIN Jihua. Phantom Study on the Influence of CT Model and Tube Voltage on Image Quality[J]. CT Theory and Applications, 2022, 31(3): 345-350. DOI: 10.15953/j.ctta.2021.042
    [5]XIA Zhenying, WU Dan, YU Jianan, LI Siyuan, SONG Wenyan. The Influence of Different Noise Indexes on Chest CT Image Quality for Patients with PCP[J]. CT Theory and Applications, 2019, 28(2): 221-228. DOI: 10.15953/j.1004-4140.2019.28.02.08
    [6]BU Yu-lian, ZHANG Huan, PAN Zi-lai, YANG Wen-jie, CHEN Ke-min, YAN Fu-hua. The Study of the Image Quality of Dual Energy Spectral CT in the Assessment of Myocardial Infarction[J]. CT Theory and Applications, 2016, 25(3): 279-286. DOI: 10.15953/j.1004-4140.2016.25.03.04
    [7]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.
    [8]LIU Jia-bin, LI Kun-cheng, DU Xiang-ying, LI Peng-yu. Effect of Focal Spot Size on Image Quality in 64-Row MDCT Brain Imaging[J]. CT Theory and Applications, 2008, 17(2): 61-65.
    [9]SHAO Jun-ming, XU Xiao-dong, KONG Jun. Research on CT System Imaging Quality[J]. CT Theory and Applications, 2006, 15(3): 61-67.
    [10]LI Jian-ying. GEVCT–Harmony Between High Image Quality and Low X-ray Dose[J]. CT Theory and Applications, 2006, 15(3): 57-60.

Catalog

    Article views (386) PDF downloads (9) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return