ISSN 1004-4140
CN 11-3017/P
YU Tao, DAN Hua, JIANG Wenwen. To Investigate the Application of Low-dose Contrast Agent Combined with Low Monitoring Threshold in CTA of the Head and Neck[J]. CT Theory and Applications, 2019, 28(4): 455-461. DOI: 10.15953/j.1004-4140.2019.28.04.06
Citation: YU Tao, DAN Hua, JIANG Wenwen. To Investigate the Application of Low-dose Contrast Agent Combined with Low Monitoring Threshold in CTA of the Head and Neck[J]. CT Theory and Applications, 2019, 28(4): 455-461. DOI: 10.15953/j.1004-4140.2019.28.04.06

To Investigate the Application of Low-dose Contrast Agent Combined with Low Monitoring Threshold in CTA of the Head and Neck

More Information
  • Received Date: April 23, 2019
  • Available Online: November 07, 2021
  • Published Date: August 24, 2019
  • Objective: To investigate the application of Philips Brilliance ICT with low-dose contrast agent combined with low monitoring threshold in CTA of the head and neck.Materials and Methods: Sixty patients requiring CTA of the head and neck in our hospital were selected and randomly divided into group A(observation group) and group B(experimental group), which received different injections and scanning scheme, respectively.A(observation group) contrast agent 60 mL, saline 40 mL, Monitoring Threshold 150 HU;B(experimental group) contrast agent 40 mL, saline 40 mL, Monitoring Threshold 90 HU;injection rate of both groups were 5.0 mL/s, monitoring the aortic arch.The images in the 2 groups were subjectively evaluated(visual observation) and objectively evaluated(the measurement of CT values of the superior vena cava, aortic arch, left and right common carotid artery, left and right middle cerebral artery), respectively, for the analysis of the quality of images.Results: (1) The subjective evaluation showed that all images in group A and group B could meet the diagnostic requirements.In group B, the contrast agent residue in the superior vena cava reduced significantly.(2) The scores of images quality in group A and group B presented no statistical significance(P>0.05).3.Comparison of the CT values of the superior vena cava, aortic arch, left and right common carotid artery, left and right middle cerebral artery between group A and group B showed statistical significance(P<0.05).Conclusion: Although the application of Philips Brilliance ICT with 40 ml of contrast agent combined with monitoring threshold of 90 HU in CTA of the head and neck shows differences in CT values of the images, the quality of the images can fully meet the clinical diagnostic requirements.In addition, with the quality of images ensured, the contrast agent dose and contrast agent residue in the superior vena cava are reduced.
  • Related Articles

    [1]HUANG Xiaoying, LI Xiamin, GUO Fangkai, WANG Pengchao, SHAN Chunhui, BAO Yunfeng. Combining Low-dose Perfusion with Dual-energy CT Scanning for Pancreatic Neuroendocrine Tumors[J]. CT Theory and Applications, 2025, 34(3): 369-375. DOI: 10.15953/j.ctta.2024.348
    [2]RAN Xueqi, LI Jianfeng, CAO Shaoai. Analysis of the Manifestations of ENT in Low-dose Oral CBCT Examination[J]. CT Theory and Applications, 2022, 31(3): 392-398. DOI: 10.15953/j.ctta.2021.035
    [3]SHU Yi, YANG Pei, LIAO Zilin, LI Zhenlin, TANG Jing. To Explore the Low-dose CT and QCT “One-stop-shop”Scan Technology for Physical Examination Crowd[J]. CT Theory and Applications, 2022, 31(2): 244-250. DOI: 10.15953/j.1004-4140.2022.31.02.12
    [4]CAI Ning, WANG Shijie, CHEN Lujie, ZHANG Yikun, CHEN Yang, LUO Shouhua, GU Ning. Low-dose Micro-CT Imaging Method Based on Progressive Network Processing[J]. CT Theory and Applications, 2020, 29(4): 435-446. DOI: 10.15953/j.1004-4140.2020.29.04.06
    [5]XIA Zhenying, SUN Jun, WANG Xing, WU Dan, DING Jinli, LI Hongjun. Application of iDose4 Iterative Reconstruction on Low Dose CT Scanning in AIDS Patients with PJP[J]. CT Theory and Applications, 2020, 29(2): 195-202. DOI: 10.15953/j.1004-4140.2020.29.02.10
    [6]HU Qi-yun, DONG Yue, ZHANG Rui, WANG Fei-fei, DONG Rui-tong, LUO Ya-hong, WANG Zhang-de. The Study of Low-dose Computed Tomography with Iterative Reconstruction in Neck[J]. CT Theory and Applications, 2018, 27(4): 447-453. DOI: 10.15953/j.1004-4140.2018.27.04.04
    [7]LIANG Zhen-hua, FANG Ting-song, HUANG Yu-jian, PAN Bang-sheng, LI Jun-hong. Application of Low Dose CT Scanning in the Sacroiliac Joint of Adolescents[J]. CT Theory and Applications, 2018, 27(1): 71-76. DOI: 10.15953/j.1004-4140.2018.27.01.09
    [8]TAN Zheng-wu, REN Ke. Application Status and Research Trends of the Low-dose CT Perfusion Imaging of Pancreas[J]. CT Theory and Applications, 2015, 24(6): 865-872. DOI: 10.15953/j.1004-4140.2015.24.06.13
    [9]ZHANG Chao-liang, GUAN Yu-bao, LIN Han-fei, CHEN Huai, ZENG Qing-si. Application Study of Low-dose 128-Slice Spiral CT Coronary Artery Angiography[J]. CT Theory and Applications, 2012, 21(4): 753-759.
    [10]LI Ruo-mei, WANG Si-wei, JIN Dan-dan. Low-dose CT Coronary Angiography with Status Quo of Tube Current and Voltage Parameters Optimization[J]. CT Theory and Applications, 2012, 21(3): 515-520.
  • Cited by

    Periodical cited type(2)

    1. 闵华,张陈斌,张宏远,李伟民. 原发性肠脂垂炎20例CT表现及鉴别诊断. 中国乡村医药. 2019(23): 42-43 .
    2. 董健,杨磊,颜煖,温静,张春燕,陈孝柏,温廷国,王仁贵. 冠状动脉CTA在冠状动脉-肺动脉瘘中诊断价值的回顾性研究. CT理论与应用研究. 2017(04): 519-524 . 本站查看

    Other cited types(0)

Catalog

    Article views (337) PDF downloads (7) Cited by(2)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return