ISSN 1004-4140
CN 11-3017/P
ZHANG Lingyun, YANG Shu, WANG Fuqiang. Imaging Analysis of Pseudolesion Caused by Abnormal Gastric Venous Drainage[J]. CT Theory and Applications, 2020, 29(6): 718-725. DOI: 10.15953/j.1004-4140.2020.29.06.10
Citation: ZHANG Lingyun, YANG Shu, WANG Fuqiang. Imaging Analysis of Pseudolesion Caused by Abnormal Gastric Venous Drainage[J]. CT Theory and Applications, 2020, 29(6): 718-725. DOI: 10.15953/j.1004-4140.2020.29.06.10

Imaging Analysis of Pseudolesion Caused by Abnormal Gastric Venous Drainage

More Information
  • Received Date: March 15, 2020
  • Available Online: November 10, 2021
  • Objective:To analyze the imaging features of focal sparing in fatty liver caused by abnormal gastric venous drainage and its formation mechanism. Methods:The imaging features of pseudolesion caused by abnormal gastric venous drainage in 15 cases were analyzed retrospectively. Results:All the 15 cases had clear boundary, and the diameter of abnormal gastric vein ranged from 1.5 to 6 mm. In 14 cases, the right gastric vein was used to drain the liver, among which 3 cases were located in segment Ⅰ, 4 cases were located in segment Ⅲ, 6 cases were located in segment Ⅳ dorsal, and 1 case occupied the left liver. The left gastric vein was draining in 1 case, and the focal sparing was located in segment Ⅲ. Among the 15 cases, 11 cases had the appearance of mass(5 cases were round and 6 cases were wedge-shaped). The 2 cases located in segment Ⅰ were almost identical with caudate lobe, and were accompanied by different degrees of caudate lobe hypertrophy. One case occupied the left liver; one case presented irregular "claw-like" changes along the draining vein. Conclusion:The formation of focal sparing in fatty liver is related to abnormal gastric venous drainage, the correct diagnosis can be made by fully grasping the imaging characteristics.
  • Related Articles

    [1]GAO Jun, ZHANG Hu, ZHAO Jian, XU Jiajun. Computed Tomography Diagnosis of a Giant Ganglioneuroma of the Mediastinum[J]. CT Theory and Applications, 2024, 33(1): 71-75. DOI: 10.15953/j.ctta.2023.019
    [2]HAO Qi, LIU Xiaoyan, ZHANG Yan, LI Xingpeng, ZHANG Yimeng, LIU Mengke, ZHANG Xiaojie, LI Ling, GUO Jia, DU Changyue, SUN Ying, HUO Meng, ZHANG Mingxia, LIU Wei, DUAN Yongli, DUAN Shuhong, WANG Rengui. The Clinical Value of Thin-section Chest Computed Tomography Scan for the Classification of Coronavirus Disease 2019 (COVID-19)[J]. CT Theory and Applications, 2023, 32(5): 675-683. DOI: 10.15953/j.ctta.2023.041
    [3]LI Xingpeng, YUAN Hui, DU Changyue, LIU Xiaoyan, LI Ling, LIU Mengke, ZHANG Yimeng, ZHANG Yan, HAO Qi, DUAN Shuhong, WANG Rengui. Analysis of Thin Slice Computed Tomography Features of Coronavirus Disease 2019 Related Vascular Abnormalities[J]. CT Theory and Applications, 2023, 32(5): 667-674. DOI: 10.15953/j.ctta.2023.026
    [4]XIONG Shan, CHEN Bo, MAO Jie, LIU Sibin, HUANG Yuanyi, CHENG Jianmin. Application of Computer-aided Diagnosis System Based on Deep Learning in Rib Fracture Diagnosis[J]. CT Theory and Applications, 2022, 31(5): 617-622. DOI: 10.15953/j.1004-4140.2022.31.05.08
    [5]LIU Lijun, HAO Fen'e, SUN Zhenting, MENG Lingxin, YANG Zhenxing, ZHAO Lei. Computer-aided Detection Low-dose CT for Early Lung Cancer Screening: A Feasibility Study[J]. CT Theory and Applications, 2019, 28(1): 39-44. DOI: 10.15953/j.1004-4140.2019.28.01.04
    [6]ZHU Hua-qiang, LIU Si-run, QIU Jian, LUO Dong-mei, ZHOU De-ming. X-ray and CT Image Analysis of Pelvic Fractures[J]. CT Theory and Applications, 2011, 20(1): 83-90.
    [7]YU Hong-sheng, JI Liu-zhou. Diagnosis of Esophageal Cancer by X-ray Barium Meal and CT Scan[J]. CT Theory and Applications, 2009, 18(3): 102-109.
    [8]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [9]HUANG Shao-quan, TAN Jiang-cheng, CHEN Shu-ke, LONG Hai-dan. X-ray and CT study of esophageal cancer[J]. CT Theory and Applications, 2003, 12(3): 31-33.
    [10]Li Yubin, Li Xiangliang, Zhang Kuixiang, Cao Xulong. X-Ray Computed Micro-tomography(CMT) and Its Application to Petroleum Research[J]. CT Theory and Applications, 2000, 9(3): 35-40.
  • Cited by

    Periodical cited type(0)

    Other cited types(1)

Catalog

    Article views (355) PDF downloads (8) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return