ISSN 1004-4140
CN 11-3017/P
SU D Y, HOU P, ZHANG H R, et al. Research Progress on Reducing Metal Artifacts in CT Imaging[J]. CT Theory and Applications, 2025, 34(3): 1-7. DOI: 10.15953/j.ctta.2024.023. (in Chinese).
Citation: SU D Y, HOU P, ZHANG H R, et al. Research Progress on Reducing Metal Artifacts in CT Imaging[J]. CT Theory and Applications, 2025, 34(3): 1-7. DOI: 10.15953/j.ctta.2024.023. (in Chinese).

Research Progress on Reducing Metal Artifacts in CT Imaging

More Information
  • Received Date: January 31, 2024
  • Revised Date: April 06, 2024
  • Accepted Date: April 08, 2024
  • Available Online: May 14, 2024
  • Intracranial aneurysm embolization, oral metal implants, spinal internal fixation, hip replacement, and other metal implants are increasingly used in clinical practice. Metal artifacts generated by computed tomography (CT) images during the evaluation of patients after placement of metal implants will prevent CT images from clearly showing the metal–bone interface and the adjacent tissue structure, which affects the accuracy of doctors' diagnosis. With the development of CT, metal artifact reduction technology and virtual monoenergetic imaging technology are helpful to reduce metal artifacts in CT imaging. The emergence of deep learning reconstruction algorithms and photon counting CT provides a more reliable basis for the accurate evaluation of metal implants after surgery. This paper reviews the progress of research on reducing metal artifacts in CT imaging.

  • [1]
    李昊翔, 朱凯, 孙重阳, 等. 宝石能谱CT在减少金属伪影方面的应用进展[J]. 中国医药导报, 2015, 12(11): 42-45.

    LI H X, ZHU K, SUN C Y, et al. Advances in the application of gemstone spectral CT in reducing metal artifacts[J]. China Medicine Guide, 2015, 12(11): 42-45. (in Chinese).
    [2]
    JEONG S, KIM S H, HWANG E J, et al. Usefulness of a metal artifact reduction algorithm for orthopedic implants in abdominal CT: Phantom and clinical study results[J]. American Journal of Roentgenology, 2015, 204(2): 307-317. DOI: 10.2214/ajr.14.12745.
    [3]
    PESSIS E, CAMPAGNA R, SVERZUT J M, et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: Reduction of metal artifacts at CT[J]. Radiographics, 2013, 33(2): 573-583. DOI: 10.1148/rg.332125124.
    [4]
    LEE Y H, PARK K K, SONG H T, et al. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software[J]. European Radiology, 2012, 22(6): 1331-1340. DOI: 10.1007/s00330-011-2370-5.
    [5]
    汪涛, 夏文军, 赵云松, 等. CT金属伪影去除研究进展[J]. 中国体视学与图像分析, 2020, 25(3): 207-223. DOI: 10.1148/rg.332125124.

    WANG T, XIA W J, ZHAO Y S, et al. Advances in metal artifact removal in CT[J]. Chinese Journal of Stereology and Image Analysis, 2020, 25(3): 207-223. DOI: 10.1148/rg.332125124. (in Chinese).
    [6]
    KOHYAMA S, YOSHII Y, OKAMOTO Y, et al. Advances in bone joint imaging-metal artifact reduction[J]. Diagnostics (Basel), 2022, 12(12). DOI: 10.3390/diagnostics12123079.
    [7]
    魏亦龙, 崔钢, 张跃, 等. 口腔不同金属材料全冠修复体CT成像伪影的实验研究[J]. 海南医学院学报, 2013, 19(12): 1764-1766, 1770. DOI: 10.13210/j.cnki.jhmu.2013.12.166.

    WEI Y L, CUI G, ZHANG Y, et al. Experimental study on CT imaging artifacts of dental crowns made of different metal materials[J]. Journal of Hainan Medical College, 2013, 19(12): 1764-1766, 1770. DOI: 10.13210/j.cnki.jhmu.2013.12.166. (in Chinese).
    [8]
    黄钟杰, 曹楚瑜, 刘源. 宝石能谱CT去除金属伪影软件减除脊柱和髋关节植入金属物伪影的价值[J]. 汕头大学医学院学报, 2014, 27(2): 115-118. DOI: 10.13401/j.cnki.jsumc.2014.02.024.

    HUANG Z J, CAO C Y, LIU Y. The value of gemstone spectral CT metal artifact removal software in reducing metal artifacts of spinal and hip implants[J]. Journal of Shantou University Medical College, 2014, 27(2): 115-118. DOI: 10.13401/j.cnki.jsumc.2014.02.024. (in Chinese).
    [9]
    BARRETT J F, KEAT N. Artifacts in CT: Recognition and avoidance[J]. Radiographics, 2004, 24(6): 1679-1691. DOI: 10.1148/rg.246045065.
    [10]
    NEROLADAKI A, MARTIN S P, BAGETAKOS I, et al. Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging[J]. Medicine (Baltimore), 2019, 98(6): e14341. DOI: 10.1097/md.0000000000014341.
    [11]
    WINKLHOFER S, BENNINGER E, SPROSS C, et al. CT metal artefact reduction for internal fixation of the proximal humerus: Value of mono-energetic extrapolation from dual-energy and iterative reconstructions[J]. Clinical Radiology, 2014, 69(5): e199-206. DOI: 10.1016/j.crad.2013.12.011.
    [12]
    NIKBIN A, DALILI KAJAN Z, TARAMSARI M, et al. Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study[J]. Imaging Science in Dentistry, 2018, 48(4): 245-254. DOI: 10.5624/isd.2018.48.4.245.
    [13]
    JOHNSON T R, KRAUSS B, SEDLMAIR M, et al. Material differentiation by dual energy CT: Initial experience[J]. European Radiology, 2007, 17(6): 1510-1517. DOI: 10.1007/s00330-006-0517-6.
    [14]
    HAN S C, CHUNG Y E, LEE Y H, et al. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: Assessment of image quality and clinical feasibility[J]. American Journal of Roentgenology, 2014, 203(4): 788-795. DOI: 10.2214/ajr.13.10980.
    [15]
    KIDOH M, NAKAURA T, NAKAMURA S, et al. Reduction of dental metallic artefacts in CT: Value of a newly developed algorithm for metal artefact reduction (O-MAR)[J]. Clinical Radiology, 2014, 69(1): e11-16. DOI: 10.1016/j.crad.2013.08.008.
    [16]
    LI H, NOEL C, CHEN H, et al. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy[J]. Medical Physics, 2012, 39(12): 7507-7517. DOI: 10.1118/1.4762814.
    [17]
    AXENTE M, PAIDI A, Von EYBEN R, et al. Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy[J]. Medical Physics, 2015, 42(3): 1170-1183. DOI: 10.1118/1.4906245.
    [18]
    WAGENAAR D, Van der GRAAF E R, Van der SCHAAF A, et al. Quantitative comparison of commercial and non-commercial metal artifact reduction techniques in computed tomography[J]. PLoS One, 2015, 10(6): e0127932. DOI: 10.1371/journal.pone.0127932.
    [19]
    金大永, 李笑石, 耿纪刚, 等. SEMAR与AIDR 3D去金属伪影算法相结合在髋关节置换术后CT检查中的临床应用价值[J]. 临床医学研究与实践, 2022, 7(2): 82-85, 102. DOI: 10.19347/j.cnki.2096-1413.202202023.

    JIN D Y, LI X S, GENG J G, et al. Clinical application value of SEMAR combined with AIDR 3D metal artifact reduction algorithm in CT examination after hip replacement[J]. Clinical Medical Research & Practice, 2022, 7(2): 82-85, 102. DOI: 10.19347/j.cnki.2096-1413.202202023. (in Chinese).
    [20]
    LELL M M, MEYER E, KUEFNER M A, et al. Normalized metal artifact reduction in head and neck computed tomography[J]. Investigative Radiology, 2012, 47(7): 415-421. DOI: 10.1097/RLI.0b013e3182532f17.
    [21]
    YU L, LENG S, MCCOLLOUGH C H. Dual-energy CT-based monochromatic imaging[J]. American Journal of Roentgenology, 2012, 199(S5): s9-s15. DOI: 10.2214/ajr.12.9121.
    [22]
    ZHOU C, ZHAO Y E, LUO S, et al. Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures[J]. Academic Radiology, 2011, 18(10): 1252-1257. DOI: 10.1016/j.acra.2011.05.009.
    [23]
    KAZA R K, PLATT J F, COHAN R H, et al. Dual-energy CT with single- and dual-source scanners: Current applications in evaluating the genitourinary tract[J]. Radiographics, 2012, 32(2): 353-369. DOI: 10.1148/rg.322115065.
    [24]
    HAKVOORT E T, WELLENBERG R H H, STREEKSTRA G J. Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom[J]. Physica Medica, 2020, 69: 9-18. DOI: 10.1016/j.ejmp.2019.11.006.
    [25]
    KOETZIER L R, MASTRODICASA D, SZCZYKUTOWICZ T P, et al. Deep learning image reconstruction for CT: Technical principles and clinical prospects[J]. Radiology, 2023, 306(3): e221257. DOI: 10.1148/radiol.221257.
    [26]
    BUSI M, KEHL C, FRISVAD J R, et al. Metal artifact reduction in spectral X-ray CT using spectral deep learning[J]. Journal of Imaging, 2022, 8(3). DOI: 10.3390/jimaging8030077.
    [27]
    GONG H, MARSH J F, D'SOUZA K N, et al. Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT[J]. Journal of Medical Imaging (Bellingham), 2021, 8(5): 052104. DOI: 10.1117/1.Jmi.8.5.052104.
    [28]
    LIANG K, ZHANG L, YANG H, et al. Metal artifact reduction for practical dental computed tomography by improving interpolation-based reconstruction with deep learning[J]. Medical Physics., 2019, 46(12): e823-e834. DOI: 10.1002/mp.13644.
    [29]
    PARK J, KIM S H, HAN J K. Combined application of virtual monoenergetic high keV images and the orthopedic metal artifact reduction algorithm (O-MAR): Effect on image quality[J]. Abdominal Radiology (New York), 2019, 44(2): 756-765. DOI: 10.1002/mp.13644.
    [30]
    孙彤彤, 黄熙菎, 罗腾龙, 等. 双层探测器光谱CT虚拟单能量成像联合去除植入物金属伪影用于减少置换髋关节假体金属伪影[J]. 中国医学影像技术, 2023, 39(7): 1084-1088. DOI: 10.13929/j.issn.1003-3289.2023.07.030.

    SUN T T, HUANG X K, LUO T L, et al. Virtual monoenergetic imaging combined with orthopedic metal artifact reduction for reducing metal artifacts of hip prosthesis based on dual-layer detector spectral CT[J]. Chinese Journal of Medical Imaging Technology, 2023, 39(7): 1084-1088. DOI: 10.13929/j.issn.1003-3289.2023.07.030. (in Chinese).
    [31]
    BONGERS M N, SCHABEL C, THOMAS C, et al. Comparison and combination of dual-energy- and iterative-based metal artefact reduction on hip prosthesis and dental implants[J]. PLoS One, 2015, 10(11): e0143584. DOI: 10.1371/journal.pone.0143584.
    [32]
    ANHAUS J A, SCHMIDT S, KILLERMANN P, et al. Iterative metal artifact reduction on a clinical photon counting system-technical possibilities and reconstruction selection for optimal results dependent on the metal scenario[J]. Physics in Medicine and Biology, 2022, 67(11). DOI: 10.1088/1361-6560/ac71f0.
    [33]
    SCHMITT N, WUCHERPFENNIG L, ROTKOPF L T, et al. Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol[J]. European Radiology, 2023, 33(2): 803-811. DOI: 10.1007/s00330-022-09073-y.
    [34]
    张恒龙, 杨新国, 田昭俭, 等. O-MAR重建在去除颅内动脉瘤弹簧圈栓塞术后金属伪影的价值[J]. 实用医学影像杂志, 2019, 20(3): 217-220. DOI: 10.16106/j.cnki.cn14-1281/r.2019.03.001.

    ZHANG H L, YANG X G, TIAN Z J, et al. Value of O-MAR reconstruction in removing metal artifacts after coil embolization of intracranial aneurysms[J]. Journal of Practical Medical Imaging, 2019, 20(3): 217-220. DOI: 10.16106/j.cnki.cn14-1281/r.2019.03.001. (in Chinese).
    [35]
    DUNET V, BERNASCONI M, HAJDU S D, et al. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping[J]. Neuroradiology, 2017, 59(9): 845-852. DOI: 10.1007/s00234-017-1871-6.
    [36]
    余娜, 严敏, 傅浪舟, 等. 应用能谱CT技术去除颅内动脉瘤弹簧圈栓塞术后金属伪影[J]. 第三军医大学学报, 2020, 42(20): 2069-2074. DOI: 10.16016/j.1000-5404.202005207.

    YU N, YAN M, FU L Z, et al. Removal of metal artifacts after coil embolization of intracranial aneurysms using spectral CT[J]. Journal of the Third Military Medical University, 2020, 42(20): 2069-2074. DOI: 10.16016/j.1000-5404.202005207. (in Chinese).
    [37]
    董鑫, 吕国士, 刘伟, 等. 能谱CT的MONO成像联合MARs技术在颅内弹簧圈植入物伪影的应用研究[J]. 临床放射学杂志, 2016, 35(5): 794-798. DOI: 10.13437/j.cnki.jcr.2016.05.037.

    DONG X, LV G S, LIU W, et al. Application effects of energy spectral CT mono imaging technology united with MARs in removing artifacts of intracranial spring coil implant[J]. Journal of Clinical Radiology, 2016, 35(5): 794-798. DOI: 10.13437/j.cnki.jcr.2016.05.037. (in Chinese).
    [38]
    ABDOLI M, AY M R, AHMADIAN A, et al. Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm[J]. Medical Physics, 2010, 37(12): 6166-6677. DOI: 10.1118/1.3511507.
    [39]
    FELDHAUS F, BöNING G, JONCZYK M, et al. Metallic dental artifact reduction in computed tomography (Smart MAR): Improvement of image quality and diagnostic confidence in patients with suspected head and neck pathology and oral implants[J]. European Journal of Radiology, 2019, 118: 153-160. DOI: 10.1016/j.ejrad.2019.07.015.
    [40]
    唐丽, 刘星, 侯平, 等. 深度学习重建联合Smart去金属伪影算法对颈部CT图像中口腔金属植入物伪影的影响[J]. 中国医学影像技术, 2023, 39(11): 1731-1735. DOI: 10.13929/j.issn.1003-3289.2023.11.031.

    TANG L, LIU X, HOU P, et al. Effect of deep learning reconstruction combined with Smart metal artifact reduction algorithm on artifacts of dental metal implants in neck CT images[J]. Chinese Journal of Medical Imaging Technology, 2023, 39(11): 1731-1735. DOI: 10.13929/j.issn.1003-3289.2023.11.031. (in Chinese).
    [41]
    DONG Y, SHI A J, WU J L, et al. Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT[J]. European Spine Journal, 2016, 25(6): 1754-1763. DOI: 10.1007/s00586-015-4053-4.
    [42]
    WANG Y, QIAN B, LI B, et al. Metal artifacts reduction using monochromatic images from spectral CT: Evaluation of pedicle screws in patients with scoliosis[J]. European Journal of Radiology, 2013, 82(8): e360-e366. DOI: 10.1016/j.ejrad.2013.02.024.
    [43]
    RAU A, STRAEHLE J, STEIN T, et al. Photon-counting Computed Tomography (PC-CT) of the spine: Impact on diagnostic confidence and radiation dose[J]. European Radiology, 2023, 33(8): 5578-5586. DOI: 10.1007/s00330-023-09511-5.
    [44]
    张晓军. 半髋与全髋关节置换术在老年股骨颈骨折治疗中的疗效对比[J]. 中国药物与临床, 2020, 20(2): 231-233.

    ZHANG X J. A comparative study of hemiarthroplasty and total hip arthroplasty in the treatment of femoral neck fractures in the elderly[J]. Chinese Remedies & Clinics, 2020, 20(2): 231-233. (in Chinese).
    [45]
    WELLENBERG R H, BOOMSMA M F, Van OSCH J A, et al. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses[J]. European Journal of Radiology, 2017, 88: 61-70. DOI: 10.1016/j.ejrad.2017.01.002.
    [46]
    KIM Y J, CHA J G, KIM H, et al. Dual-energy and iterative metal artifact reduction for reducing artifacts due to metallic hardware: A loosening hip phantom study[J]. American Journal of Roentgenology, 2019, 212(5): 1106-1111. DOI: 10.2214/ajr.18.20413.
    [47]
    赵立, 胡志海, 刘笑颜, 等. 对比单能量图像和单能去金属伪影技术在髋关节和膝关节置换术后的应用价值[J]. 医学影像学杂志, 2022, 32(9): 1641-1645.

    ZHAO L, HU Z H, LIU X Y, et al. Comparison of the application value of monoenergetic imaging and monoenergetic metal artifact reduction technology in hip and knee arthroplasty[J]. Journal of Medical Imaging, 2022, 32(9): 1641-1645. (in Chinese).
    [48]
    KIDOH M, UTSUNOMIYA D, ODA S, et al. CT venography after knee replacement surgery: Comparison of dual-energy CT-based monochromatic imaging and single-energy metal artifact reduction techniques on a 320-row CT scanner[J]. Acta Radiologica Open, 2017, 6(2): 2058460117693463. DOI: 10.1177/2058460117693463.
    [49]
    马双, 杨楠, 祁昕, 等. 能谱CT去伪影技术在儿童消化道金属异物扫描中的应用评估[J]. 中国临床医学影像杂志, 2023, 34(12): 878-882.

    MA S, YANG N, QI X, et al. Application and evaluation of spectral CT artifact reduction technology in the scanning of metallic foreign bodies in the digestive tract of children[J]. Journal of China Clinic Medical Imaging, 2023, 34(12): 878-882. (in Chinese).
    [50]
    何亮, 唐彩银, 张继, 等. 能谱CT金属伪影抑制算法在胸部穿刺活检中的应用价值[J]. 中国CT和MRI杂志, 2023, 21(11): 50-52. DOI: 10.3969/j.issn.1672-5131.2023.11.016.

    HE L, TANG C Y, ZHANG J, et al. Application value of metal artifact reduction algorithm in spectral CT chest biopsy[J]. Chinese Journal of CT and MRI, 2023, 21(11): 50-52. DOI: 10.3969/j.issn.1672-5131.2023.11.016. (in Chinese).
    [51]
    杨帆, 曾懿. 双能量CT虚拟单能谱成像技术在TIPS术后支架评估中的应用[J]. 中国中西医结合影像学杂志, 2019, 17(3): 266-268. DOI: 10.3969/j.issn.1672-0512.2019.03.014.

    YANG F, ZENG Y. Application of virtual monoenergetic spectral imaging of dual-energy CT in stent evaluation after TIPS[J]. Chinese Journal of Integrated Traditional Chinese and Western Medicine Imaging, 2019, 17(3): 266-268. DOI: 10.3969/j.issn.1672-0512.2019.03.014. (in Chinese).

Catalog

    Article views (485) PDF downloads (106) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return