ISSN 1004-4140
CN 11-3017/P
RONG Jun-yan, LIU Wen-lei, GAO Peng, LIAO Qi-mei, LU Hong-bing. The Review of Scatter Suppression Methods in Cone Beam CT[J]. CT Theory and Applications, 2016, 25(2): 235-250. DOI: 10.15953/j.1004-4140.2016.25.02.15
Citation: RONG Jun-yan, LIU Wen-lei, GAO Peng, LIAO Qi-mei, LU Hong-bing. The Review of Scatter Suppression Methods in Cone Beam CT[J]. CT Theory and Applications, 2016, 25(2): 235-250. DOI: 10.15953/j.1004-4140.2016.25.02.15

The Review of Scatter Suppression Methods in Cone Beam CT

More Information
  • Received Date: December 02, 2015
  • Available Online: December 01, 2022
  • Published Date: April 24, 2016
  • Scatter artifacts in cone beam CT(CBCT) degrades image quality seriously, which limits the development and application of CBCT. Researchers have reviewed scatter suppression or correction methods at home and abroad. However, a few new technologies have appeared along with the advancement of scatter suppression methods. This paper analyses the effects of X-ray scattering to CT imaging and summarizes general scatter suppression methods. Also, the scatter correction framework is combed, in which the projection compensation technique and common scatter estimation methods are introduced particularly. Problems in scatter correction are concluded, in which the magnification of noises in scatter correction is emphasized. It provides use for reference to the research and development in scatter suppression.
  • Related Articles

    [1]ZHANG Hao, LEI Jianshe, SONG Xiaoyan, DENG Yue. Direct Surface-wave Tomography from Ambient Noise in the Shanxi Rift Zone and Adjacent Areas[J]. CT Theory and Applications, 2025, 34(2): 175-189. DOI: 10.15953/j.ctta.2025.002
    [2]LIU Kang, YANG Dewu, ZHANG yongxian, LIU dandan, GAI xinghui, CHEN zhaorui, GONG hao, SUI Yan. Impact of Different Scanning Modes and Noise Index on Inner Ear CT Image Quality and Radiation Dose[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.230
    [3]LIU Weina, SUN Xiaoli, DUAN Yongli, HUO Meng, ZHANG Mingxia, WANG Rengui. Application Value of Dual-Source CT Noise-Optimized Virtual Monoenergetic Imaging Technology in Portal Vein Imaging of Patients with Portal Hypertension[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.084
    [4]YAN Jie, ZHANG Lishu, HONG Heting, HUANG Quancheng, LEI Yuhang, LIAO Xiaolong, GUI Laibao, YANG Xuan. Application of Ambient Noise and Dense Seismic Array Imaging Techniques in Goaf Detection Beneath Coal Mines at Haerwusu[J]. CT Theory and Applications, 2023, 32(4): 461-470. DOI: 10.15953/j.ctta.2023.023
    [5]LI Guihua, WANG Jingqi, XU Yun, ZHANG Wenbo, WANG Shulin. Random Noise Simulation Method for Seismic Exploration Based on Typical Decomposition[J]. CT Theory and Applications, 2019, 28(6): 659-667. DOI: 10.15953/j.1004-4140.2019.28.06.03
    [6]XIA Zhenying, WU Dan, YU Jianan, LI Siyuan, SONG Wenyan. The Influence of Different Noise Indexes on Chest CT Image Quality for Patients with PCP[J]. CT Theory and Applications, 2019, 28(2): 221-228. DOI: 10.15953/j.1004-4140.2019.28.02.08
    [7]WU Wen-shu, WANG Zhe, SHI Yi-fan, ZHAO Zhan-shan, WEI Cun-feng, WEI Long. Noise Reduction for Low-dose CT Sinogram Based on PDE[J]. CT Theory and Applications, 2017, 26(2): 177-188. DOI: 10.15953/j.1004-4140.2017.26.02.06
    [8]SHI Cheng-cheng, LU Lai-yu, WANG Chun-yong, HE Zheng-qin, DING Zhi-feng. Rayleigh-wave Tomography Based on Ambient Seismic Noise in the Central and Western Blocks of the North China Craton[J]. CT Theory and Applications, 2014, 23(1): 53-64.
    [9]WANG Tian-tian, YU Xiao-e. Identifying of Noise Types for Computed Tomography Images Based on Wavelet Analysis[J]. CT Theory and Applications, 2011, 20(2): 183-190.
    [10]HU Dong-cai, CHEN Hao, ZHANG Ding-hua. Scatter Correction Method for Flat-Panel Detector-Based Cone Beam CT[J]. CT Theory and Applications, 2009, 18(1): 16-22.

Catalog

    Article views (648) PDF downloads (55) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return