ISSN 1004-4140
CN 11-3017/P
HUANG Zhen, YIN Chun-tao, CHEN Wang, YAO Xuan-jun, QIAN Bin. Diagnostic Value of CT Spectrum Imaging on Micrometastases of Liver[J]. CT Theory and Applications, 2018, 27(4): 439-445. DOI: 10.15953/j.1004-4140.2018.27.04.03
Citation: HUANG Zhen, YIN Chun-tao, CHEN Wang, YAO Xuan-jun, QIAN Bin. Diagnostic Value of CT Spectrum Imaging on Micrometastases of Liver[J]. CT Theory and Applications, 2018, 27(4): 439-445. DOI: 10.15953/j.1004-4140.2018.27.04.03

Diagnostic Value of CT Spectrum Imaging on Micrometastases of Liver

More Information
  • Received Date: April 01, 2018
  • Available Online: November 07, 2021
  • Published Date: August 24, 2018
  • Objective: The effect of CT spectroscopy in the diagnosis of liver micrometastases and the effect on the liver function of the patients. Methods: Methods 80 cases of hepatic micrometastases in our hospital from May 2015 to May-2017 were retrospective analyzed and divided into two groups according to different diagnostic methods. The control group was given conventional CT diagnosis, and the study group was diagnosed by CT energy spectrum imaging. Results: Comparison of diagnostic results, the number of lesions in study group diagnosed and the detection rate was significantly higher than the control group (<i<P</i<<0.05), at the same time, loss rate and error rate were lower than the control group (<i<P</i<<0.05); diagnosis method used in study group the sensitivity, specificity and positive predictive value were higher than the control group (<i<P</i<<0.05); contrast treatment, efficacy of study group was significantly better than the control group (<i<P</i<<0.05). Conclusion: The application of CT spectroscopy in the diagnosis of liver micrometastases is helpful for early detection and early treatment, and has higher diagnostic value. It is beneficial for patients to improve liver function, and is worthy of clinical application.
  • Related Articles

    [1]GUO Yu, LIU Jianli. Advances in CT Functional Imaging and Artificial Intelligence for Assessing Esophageal Varices in Cirrhosis[J]. CT Theory and Applications, 2025, 34(4): 720-726. DOI: 10.15953/j.ctta.2024.116
    [2]ZHOU Dongmei, YIN Guixiu. CT Spectral Imaging Study in Patients with Carotid Body Tumors at High Altitudes[J]. CT Theory and Applications, 2023, 32(1): 81-89. DOI: 10.15953/j.ctta.2022.059
    [3]ZHOU Yong, ZHOU Cheng, GAN Xiaojing, YU Yingying, YANG Fan, WEN Zhi. Value of Gemstone Energy Spectrum CT Multi-parameter Imaging in Differential Diagnosis and Preoperative Staging of Liver Tumors[J]. CT Theory and Applications, 2019, 28(5): 601-607. DOI: 10.15953/j.1004-4140.2019.28.05.10
    [4]HUA Chenchen, LIU Yao, YIN Qihua. The Study of Accurate Liver Volume Measurement by IQQA-liver Auto Analysis Software[J]. CT Theory and Applications, 2019, 28(2): 229-235. DOI: 10.15953/j.1004-4140.2019.28.02.09
    [5]YANG Xiao-feng, ZHA Yun-fei, LI Liang. Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor[J]. CT Theory and Applications, 2016, 25(6): 717-723. DOI: 10.15953/j.1004-4140.2016.25.06.13
    [6]CHENG Guan-xun, YAN Jing, LIU Guo-shun, YU Kang-hui. Diagnostic Value of Hypertrophic Cardiomyopathy by Dual-source CT Functional Imaging[J]. CT Theory and Applications, 2014, 23(1): 9-17.
    [7]XIA Zhen-ying, CHEN Feng, LI Hong-jun. Influence of Different Injection Rates of Contrast Medium with 64-slice Helical CT on Effect of Liver Arterial Phase Enhanced Scanning[J]. CT Theory and Applications, 2012, 21(1): 89-96.
    [8]ZHANG Yuan, SUN Yong-guang, GAO Shu-ming, HAN Xiang-jun. CT Perfusion Imaging of the Liver and Its Study Headway[J]. CT Theory and Applications, 2007, 16(1): 70-76.
    [9]SUN Li-xin, WANG Li, WANG Hong-tao, MA Hui, YUAN Ling-jin. Significance on Diagnosing Fatty Liver of Limitation by CT[J]. CT Theory and Applications, 2003, 12(1): 27-29.
    [10]Yan Gang. Functions of Multi-row Helical CT Using in Medical Diagnosis[J]. CT Theory and Applications, 2001, 10(4): 38-41.
  • Cited by

    Periodical cited type(1)

    1. 朱芸,孟炎. CT能谱成像在肝细胞肝癌与局灶性结节增生鉴别诊断中的应用效果. 中外医疗. 2019(36): 180-182 .

    Other cited types(0)

Catalog

    Article views (493) PDF downloads (7) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return